Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control parameters into DcBus and PowerPort classes. This will help to manage current from different sources (grid, solar) going towards one bus and control the battery voltage. It will also help to align multiple charge controllers in parallel, communicating via CAN bus.
This commit is contained in:
+8
-7
@@ -22,11 +22,13 @@
|
||||
|
||||
#include "tests.h"
|
||||
|
||||
PowerPort lv_terminal; // low voltage terminal (battery for typical MPPT)
|
||||
DcBus lv_bus;
|
||||
PowerPort lv_terminal(&lv_bus); // low voltage terminal (battery for typical MPPT)
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
PowerPort hv_terminal; // high voltage terminal (solar for typical MPPT)
|
||||
PowerPort dcdc_lv_port; // internal low voltage side of DC/DC converter
|
||||
DcBus hv_bus;
|
||||
PowerPort hv_terminal(&hv_bus); // high voltage terminal (solar for typical MPPT)
|
||||
PowerPort dcdc_lv_port(&lv_bus); // internal low voltage side of DC/DC converter
|
||||
#if CONFIG_HV_TERMINAL_NANOGRID
|
||||
Dcdc dcdc(&hv_terminal, &dcdc_lv_port, MODE_NANOGRID);
|
||||
#elif CONFIG_HV_TERMINAL_BATTERY
|
||||
@@ -37,13 +39,12 @@ Dcdc dcdc(&hv_terminal, &dcdc_lv_port, MODE_MPPT_BUCK);
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
PowerPort pwm_terminal; // external terminal of PWM switch port (normally solar)
|
||||
PowerPort pwm_port_int; // internal side of PWM switch
|
||||
PwmSwitch pwm_switch(&pwm_terminal, &pwm_port_int);
|
||||
PowerPort pwm_terminal(&lv_bus); // internal side of PWM switch
|
||||
PwmSwitch pwm_switch(&pwm_terminal);
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_LOAD_OUTPUT
|
||||
PowerPort load_terminal; // load terminal (also connected to lv_bus)
|
||||
PowerPort load_terminal(&lv_bus); // load terminal (also connected to lv_bus)
|
||||
LoadOutput load(&load_terminal);
|
||||
#endif
|
||||
|
||||
|
||||