Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control parameters into DcBus and PowerPort classes. This will help to manage current from different sources (grid, solar) going towards one bus and control the battery voltage. It will also help to align multiple charge controllers in parallel, communicating via CAN bus.
This commit is contained in:
+4
-4
@@ -140,8 +140,8 @@ void LoadOutput::control()
|
||||
// long-term overvoltage (overvoltage transients are detected as an ADC alert and switch
|
||||
// off the solar input instead of the load output)
|
||||
static int debounce_counter = 0;
|
||||
if (port->voltage > port->sink_voltage_max ||
|
||||
port->voltage > LOW_SIDE_VOLTAGE_MAX)
|
||||
if (port->bus->voltage > port->sink_voltage_max ||
|
||||
port->bus->voltage > LOW_SIDE_VOLTAGE_MAX)
|
||||
{
|
||||
debounce_counter++;
|
||||
if (debounce_counter >= CONTROL_FREQUENCY) { // waited 1s before setting the flag
|
||||
@@ -178,8 +178,8 @@ void LoadOutput::control()
|
||||
}
|
||||
|
||||
if (dev_stat.has_error(ERR_LOAD_OVERVOLTAGE) &&
|
||||
port->voltage < (port->sink_voltage_max - ov_hysteresis) &&
|
||||
port->voltage < (LOW_SIDE_VOLTAGE_MAX - ov_hysteresis))
|
||||
port->bus->voltage < (port->sink_voltage_max - ov_hysteresis) &&
|
||||
port->bus->voltage < (LOW_SIDE_VOLTAGE_MAX - ov_hysteresis))
|
||||
{
|
||||
dev_stat.clear_error(ERR_LOAD_OVERVOLTAGE);
|
||||
}
|
||||
|
||||
Reference in New Issue