Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control parameters into DcBus and PowerPort classes. This will help to manage current from different sources (grid, solar) going towards one bus and control the battery voltage. It will also help to align multiple charge controllers in parallel, communicating via CAN bus.
This commit is contained in:
+17
-17
@@ -154,17 +154,15 @@ void daq_update()
|
||||
//int vcc = 3300;
|
||||
|
||||
// calculate lower voltage first, as it is needed for PWM terminal voltage calculation
|
||||
lv_terminal.voltage = adc_scaled(ADC_POS_V_BAT, vcc, ADC_GAIN_V_BAT);
|
||||
load_terminal.voltage = lv_terminal.voltage;
|
||||
lv_bus.voltage = adc_scaled(ADC_POS_V_BAT, vcc, ADC_GAIN_V_BAT);
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
hv_terminal.voltage = adc_scaled(ADC_POS_V_SOLAR, vcc, ADC_GAIN_V_SOLAR);
|
||||
dcdc_lv_port.voltage = lv_terminal.voltage;
|
||||
hv_bus.voltage = adc_scaled(ADC_POS_V_SOLAR, vcc, ADC_GAIN_V_SOLAR);
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
pwm_terminal.voltage = lv_terminal.voltage - vcc * (ADC_OFFSET_V_SOLAR / 1000.0) -
|
||||
pwm_switch.ext_voltage = lv_bus.voltage - vcc * (ADC_OFFSET_V_SOLAR / 1000.0) -
|
||||
adc_scaled(ADC_POS_V_SOLAR, vcc, ADC_GAIN_V_SOLAR);
|
||||
pwm_port_int.voltage = lv_terminal.voltage;
|
||||
#endif
|
||||
|
||||
load_terminal.current =
|
||||
@@ -172,25 +170,27 @@ void daq_update()
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
// current multiplied with PWM duty cycle for PWM charger to get avg current for correct power calculation
|
||||
pwm_port_int.current = pwm_switch.get_duty_cycle() * (
|
||||
pwm_terminal.current = -pwm_switch.get_duty_cycle() * (
|
||||
adc_scaled(ADC_POS_I_SOLAR, vcc, ADC_GAIN_I_SOLAR) + solar_current_offset);
|
||||
pwm_terminal.current = -pwm_port_int.current;
|
||||
lv_terminal.current = pwm_port_int.current - load_terminal.current;
|
||||
|
||||
pwm_port_int.power = pwm_port_int.voltage * pwm_port_int.current;
|
||||
pwm_terminal.power = pwm_terminal.voltage * pwm_terminal.current;
|
||||
lv_terminal.current = -pwm_terminal.current - load_terminal.current;
|
||||
|
||||
pwm_terminal.power = pwm_terminal.bus->voltage * pwm_terminal.current;
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
dcdc_lv_port.current =
|
||||
adc_scaled(ADC_POS_I_DCDC, vcc, ADC_GAIN_I_DCDC) + solar_current_offset;
|
||||
lv_terminal.current = dcdc_lv_port.current - load_terminal.current;
|
||||
hv_terminal.current = -dcdc_lv_port.current * lv_terminal.voltage / hv_terminal.voltage;
|
||||
|
||||
dcdc_lv_port.power = dcdc_lv_port.voltage * dcdc_lv_port.current;
|
||||
hv_terminal.power = hv_terminal.voltage * hv_terminal.current;
|
||||
lv_terminal.current = dcdc_lv_port.current - load_terminal.current;
|
||||
|
||||
hv_terminal.current = -dcdc_lv_port.current * lv_terminal.bus->voltage / hv_terminal.bus->voltage;
|
||||
|
||||
dcdc_lv_port.power = dcdc_lv_port.bus->voltage * dcdc_lv_port.current;
|
||||
hv_terminal.power = hv_terminal.bus->voltage * hv_terminal.current;
|
||||
#endif
|
||||
lv_terminal.power = lv_terminal.voltage * lv_terminal.current;
|
||||
load_terminal.power = load_terminal.voltage * load_terminal.current;
|
||||
lv_terminal.power = lv_terminal.bus->voltage * lv_terminal.current;
|
||||
load_terminal.power = load_terminal.bus->voltage * load_terminal.current;
|
||||
|
||||
#ifdef PIN_ADC_TEMP_BAT
|
||||
// battery temperature calculation
|
||||
|
||||
Reference in New Issue