Implemented maximum voltage check for DC/DC
This commit is contained in:
+10
-2
@@ -28,8 +28,8 @@ void dcdc_init(dcdc_t *dcdc)
|
||||
dcdc->mode = DCDC_MODE_INIT;
|
||||
dcdc->ls_current_max = DCDC_CURRENT_MAX;
|
||||
dcdc->ls_current_min = 0.05; // A if lower, charger is switched off
|
||||
dcdc->hs_voltage_max = 55.0; // V
|
||||
dcdc->ls_voltage_max = 30.0; // V
|
||||
dcdc->hs_voltage_max = HIGH_SIDE_VOLTAGE_MAX; // V
|
||||
dcdc->ls_voltage_max = LOW_SIDE_VOLTAGE_MAX; // V
|
||||
//dcdc->offset_voltage_start = 4.0; // V charging switched on if Vsolar > Vbat + offset
|
||||
//dcdc->offset_voltage_stop = 1.0; // V charging switched off if Vsolar < Vbat + offset
|
||||
dcdc->restart_interval = 60; // s --> when should we retry to start charging after low solar power cut-off?
|
||||
@@ -109,8 +109,16 @@ void dcdc_control(dcdc_t *dcdc, power_port_t *hs, power_port_t *ls)
|
||||
dcdc->off_timestamp = time(NULL);
|
||||
printf("DC/DC stop.\n");
|
||||
}
|
||||
if (ls->voltage > dcdc->ls_voltage_max || hs->voltage > dcdc->hs_voltage_max) {
|
||||
half_bridge_stop();
|
||||
dcdc->off_timestamp = time(NULL);
|
||||
printf("DC/DC emergency stop (voltage limits exceeded).\n");
|
||||
}
|
||||
}
|
||||
else {
|
||||
if (ls->voltage > dcdc->ls_voltage_max || hs->voltage > dcdc->hs_voltage_max) {
|
||||
return;
|
||||
}
|
||||
if (_dcdc_check_start_conditions(dcdc, ls, hs)) {
|
||||
// Vmpp at approx. 0.8 * Voc --> take 0.9 as starting point for MPP tracking
|
||||
half_bridge_start(ls->voltage / (hs->voltage * 0.9));
|
||||
|
||||