DC bus and terminal naming improved
- DcBus representing actual screw terminals renamed - Internal DC bus at DC/DC low voltage side added for correct DC/DC control - DC/DC struct now stores pointers to HV and LV bus objects. Redundant voltage and current measurement variables removed. - Unit tests updated DC/DC control needs further improvements to make use of the changes
This commit is contained in:
+41
-36
@@ -45,17 +45,19 @@
|
||||
Serial serial(PIN_SWD_TX, PIN_SWD_RX, "serial", 115200);
|
||||
|
||||
Dcdc dcdc = {};
|
||||
DcBus hv_bus = {}; // high voltage side (solar for typical MPPT)
|
||||
DcBus lv_bus = {}; // low voltage side (battery for typical MPPT)
|
||||
DcBus *bat_bus = NULL;
|
||||
DcBus load_bus = {}; // load terminal
|
||||
PwmSwitch pwm_switch = {}; // only necessary for PWM charger
|
||||
BatConf bat_conf; // actual (used) battery configuration
|
||||
BatConf bat_conf_user; // temporary storage where the user can write to
|
||||
Charger charger; // battery state information
|
||||
DcBus hv_terminal = {}; // high voltage terminal (solar for typical MPPT)
|
||||
DcBus lv_bus_int = {}; // internal low voltage side of DC/DC converter
|
||||
DcBus lv_terminal = {}; // low voltage terminal (battery for typical MPPT)
|
||||
DcBus load_terminal = {}; // load terminal
|
||||
DcBus *bat_terminal = NULL; // pointer to terminal where battery is connected
|
||||
DcBus *solar_terminal = NULL; // pointer to above terminal where solar panel is connected
|
||||
PwmSwitch pwm_switch = {}; // only necessary for PWM charger
|
||||
BatConf bat_conf; // actual (used) battery configuration
|
||||
BatConf bat_conf_user; // temporary storage where the user can write to
|
||||
Charger charger; // charger state information
|
||||
LoadOutput load;
|
||||
LogData log_data;
|
||||
extern ThingSet ts; // defined in data_objects.cpp
|
||||
extern ThingSet ts; // defined in data_objects.cpp
|
||||
|
||||
time_t timestamp; // current unix timestamp (independent of time(NULL), as it is user-configurable)
|
||||
|
||||
@@ -68,15 +70,15 @@ void system_control()
|
||||
static int counter = 0;
|
||||
|
||||
// convert ADC readings to meaningful measurement values
|
||||
update_measurements(&dcdc, &charger, &hv_bus, &lv_bus, &load_bus);
|
||||
update_measurements();
|
||||
|
||||
#ifdef CHARGER_TYPE_PWM
|
||||
pwm_switch_control(&pwm_switch, &hv_bus, bat_bus);
|
||||
pwm_switch_control(&pwm_switch, &hv_terminal, bat_terminal);
|
||||
leds_set_charging(pwm_switch_enabled());
|
||||
#else
|
||||
// control PWM of the DC/DC according to hs and ls port settings
|
||||
// (this function includes MPPT algorithm)
|
||||
dcdc_control(&dcdc, &hv_bus, &lv_bus);
|
||||
dcdc_control(&dcdc);
|
||||
leds_set_charging(half_bridge_enabled());
|
||||
#endif
|
||||
|
||||
@@ -88,12 +90,12 @@ void system_control()
|
||||
timestamp++;
|
||||
counter = 0;
|
||||
// energy + soc calculation must be called exactly once per second
|
||||
dc_bus_energy_balance(&hv_bus);
|
||||
dc_bus_energy_balance(&lv_bus);
|
||||
dc_bus_energy_balance(&load_bus);
|
||||
log_update_energy(&log_data, &hv_bus, &lv_bus, &load_bus);
|
||||
log_update_min_max_values(&log_data, &dcdc, &charger, &load, &hv_bus, &lv_bus, &load_bus);
|
||||
battery_update_soc(&bat_conf, &charger, bat_bus);
|
||||
dc_bus_energy_balance(&hv_terminal);
|
||||
dc_bus_energy_balance(&lv_terminal);
|
||||
dc_bus_energy_balance(&load_terminal);
|
||||
log_update_energy(&log_data, &hv_terminal, &lv_terminal, &load_terminal);
|
||||
log_update_min_max_values(&log_data, &dcdc, &charger, &load, &hv_terminal, &lv_terminal, &load_terminal);
|
||||
battery_update_soc(&bat_conf, &charger, bat_terminal);
|
||||
}
|
||||
counter++;
|
||||
}
|
||||
@@ -108,12 +110,12 @@ int main()
|
||||
battery_conf_overwrite(&bat_conf, &bat_conf_user); // initialize conf_user with same values
|
||||
charger_init(&charger);
|
||||
|
||||
load_init(&load, &load_bus);
|
||||
load_init(&load, &load_terminal);
|
||||
|
||||
#ifdef CHARGER_TYPE_PWM
|
||||
pwm_switch_init(&pwm_switch);
|
||||
#else // MPPT
|
||||
dcdc_init(&dcdc);
|
||||
dcdc_init(&dcdc, &hv_terminal, &lv_bus_int);
|
||||
half_bridge_init(PWM_FREQUENCY, PWM_DEADTIME, 12 / dcdc.hs_voltage_max, 0.97); // lower duty limit might have to be adjusted dynamically depending on LS voltage
|
||||
#endif
|
||||
|
||||
@@ -128,45 +130,48 @@ int main()
|
||||
dma_setup();
|
||||
adc_timer_start(1000); // 1 kHz
|
||||
wait(0.5); // wait for ADC to collect some measurement values
|
||||
update_measurements(&dcdc, &charger, &hv_bus, &lv_bus, &load_bus);
|
||||
update_measurements();
|
||||
calibrate_current_sensors();
|
||||
|
||||
// Communication interfaces
|
||||
ts_devices.enable();
|
||||
|
||||
|
||||
uext_init();
|
||||
init_watchdog(10); // 10s should be enough for communication ports
|
||||
|
||||
#ifdef CHARGER_TYPE_PWM
|
||||
dc_bus_init_solar(&hv_bus, PWM_CURRENT_MAX);
|
||||
bat_bus = &lv_bus;
|
||||
bat_terminal = &lv_terminal;
|
||||
solar_terminal = &hv_terminal;
|
||||
dc_bus_init_solar(solar_terminal, PWM_CURRENT_MAX);
|
||||
#else
|
||||
// Setup of DC/DC power stage
|
||||
switch(dcdc.mode) {
|
||||
case MODE_NANOGRID:
|
||||
dc_bus_init_nanogrid(&hv_bus);
|
||||
bat_bus = &lv_bus;
|
||||
bat_terminal = &lv_terminal;
|
||||
dc_bus_init_nanogrid(&hv_terminal);
|
||||
break;
|
||||
case MODE_MPPT_BUCK: // typical MPPT charge controller operation
|
||||
dc_bus_init_solar(&hv_bus, DCDC_CURRENT_MAX);
|
||||
bat_bus = &lv_bus;
|
||||
bat_terminal = &lv_terminal;
|
||||
solar_terminal = &hv_terminal;
|
||||
dc_bus_init_solar(solar_terminal, DCDC_CURRENT_MAX);
|
||||
break;
|
||||
case MODE_MPPT_BOOST: // for charging of e-bike battery via solar panel
|
||||
dc_bus_init_solar(&lv_bus, DCDC_CURRENT_MAX);
|
||||
bat_bus = &hv_bus;
|
||||
bat_terminal = &hv_terminal;
|
||||
solar_terminal = &lv_terminal;
|
||||
dc_bus_init_solar(solar_terminal, DCDC_CURRENT_MAX);
|
||||
break;
|
||||
}
|
||||
#endif
|
||||
charger_detect_num_batteries(&charger, &bat_conf, bat_bus); // check if we have 24V instead of 12V system
|
||||
battery_init_dc_bus(bat_bus, &bat_conf, charger.num_batteries);
|
||||
charger_detect_num_batteries(&charger, &bat_conf, bat_terminal); // check if we have 24V instead of 12V system
|
||||
battery_init_dc_bus(bat_terminal, &bat_conf, charger.num_batteries);
|
||||
|
||||
wait(2); // safety feature: be able to re-flash before starting
|
||||
control_timer_start(CONTROL_FREQUENCY);
|
||||
wait(0.1); // necessary to prevent MCU from randomly getting stuck here if PV panel is connected before battery
|
||||
|
||||
|
||||
sleep_manager_lock_deep_sleep(); // required to have sleep returning.
|
||||
/*
|
||||
sleep_manager_lock_deep_sleep(); // required to have sleep returning.
|
||||
/*
|
||||
The mBed Serial class calls this internal during "attach", this is why it work with ThingSet Serial enabled even
|
||||
without this statement. Might be an issue of the particular STM32F072 mBed code or may affect
|
||||
also STM32L073 platforms on mBed
|
||||
@@ -184,9 +189,9 @@ int main()
|
||||
|
||||
//printf("Still alive... time: %d, mode: %d\n", (int)time(NULL), dcdc.mode);
|
||||
|
||||
charger_state_machine(bat_bus, &bat_conf, &charger);
|
||||
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
||||
|
||||
load_state_machine(&load, lv_bus.dis_allowed);
|
||||
load_state_machine(&load, lv_terminal.dis_allowed);
|
||||
|
||||
eeprom_update();
|
||||
|
||||
|
||||
Reference in New Issue