Battery config updated and started with Doxygen added
This commit is contained in:
+5
-5
@@ -16,17 +16,17 @@
|
||||
|
||||
#include "power_port.h"
|
||||
|
||||
void power_port_init_bat(power_port_t *port, battery_t *bat)
|
||||
void power_port_init_bat(power_port_t *port, battery_conf_t *bat)
|
||||
{
|
||||
port->input_allowed = true; // discharging allowed
|
||||
port->output_allowed = true; // charging allowed
|
||||
|
||||
port->voltage_input_start = bat->cell_voltage_load_reconnect * bat->num_cells;
|
||||
port->voltage_input_stop = bat->cell_voltage_load_disconnect * bat->num_cells;
|
||||
port->voltage_input_start = bat->voltage_load_reconnect;
|
||||
port->voltage_input_stop = bat->voltage_load_disconnect;
|
||||
port->current_input_max = -bat->charge_current_max; // TODO: discharge current
|
||||
|
||||
port->voltage_output_target = bat->cell_voltage_max * bat->num_cells;
|
||||
port->voltage_output_min = bat->cell_voltage_absolute_min * bat->num_cells;
|
||||
port->voltage_output_target = bat->voltage_max;
|
||||
port->voltage_output_min = bat->voltage_absolute_min;
|
||||
port->current_output_max = bat->charge_current_max;
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue
Block a user