Current compensation for load switch thresholds added

This commit is contained in:
Martin Jaeger
2019-04-18 09:23:58 +02:00
parent 666ca02baf
commit e05fd95e17
10 changed files with 73 additions and 24 deletions
+20 -6
View File
@@ -48,23 +48,29 @@ void battery_conf_init(battery_conf_t *bat, bat_type type, int num_cells, float
bat->voltage_max = num_cells * 2.4;
bat->voltage_recharge = num_cells * 2.3;
// Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated)
bat->voltage_load_disconnect = num_cells * 1.95;
bat->voltage_load_reconnect = num_cells * 2.1;
bat->voltage_load_reconnect = num_cells * 2.05; // maybe increase to 2.10, if hysteresis observed?
bat->internal_resistance = num_cells * (1.95 - 1.80) / LOAD_CURRENT_MAX; // assumption: Battery selection matching charge controller
bat->voltage_absolute_min = num_cells * 1.8;
bat->ocv_full = num_cells * 2.2;
bat->ocv_empty = num_cells * 1.9;
bat->ocv_full = num_cells * 2.15;
bat->ocv_empty = num_cells * 1.95;
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
bat->current_cutoff_CV = bat->nominal_capacity * 0.04; // 3-5 % of C/1
bat->trickle_enabled = true;
bat->time_trickle_recharge = 30*60;
// http://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
bat->voltage_trickle = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.25 : 2.3);
// Values as suggested in EN 62509:2011
bat->voltage_trickle = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.35 : 2.3);
// Enable for flooded batteries only, according to
// https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only
bat->equalization_enabled = false;
bat->voltage_equalization = num_cells * 2.5;
// Values as suggested in EN 62509:2011
bat->voltage_equalization = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.50 : 2.45);
bat->time_limit_equalization = 60*60;
bat->current_limit_equalization = (1.0 / 7.0) * bat->nominal_capacity;
bat->equalization_trigger_time = 8; // weeks
@@ -80,6 +86,7 @@ void battery_conf_init(battery_conf_t *bat, bat_type type, int num_cells, float
bat->voltage_load_disconnect = num_cells * 3.0;
bat->voltage_load_reconnect = num_cells * 3.15;
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / LOAD_CURRENT_MAX; // 5% voltage drop at max current
bat->voltage_absolute_min = num_cells * 2.0;
bat->ocv_full = num_cells * 3.4; // will give really bad SOC calculation
@@ -99,6 +106,8 @@ void battery_conf_init(battery_conf_t *bat, bat_type type, int num_cells, float
bat->voltage_load_disconnect = num_cells * 3.3;
bat->voltage_load_reconnect = num_cells * 3.6;
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / LOAD_CURRENT_MAX; // 5% voltage drop at max current
bat->voltage_absolute_min = num_cells * 2.5;
bat->ocv_full = num_cells * 4.0;
@@ -143,6 +152,8 @@ bool battery_conf_check(battery_conf_t *bat_conf)
bat_conf->voltage_recharge < (bat_conf->voltage_max - 0.4) &&
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1) &&
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4) &&
bat_conf->internal_resistance < bat_conf->voltage_load_disconnect * 0.1 / LOAD_CURRENT_MAX && // max. 10% drop
bat_conf->wire_resistance < bat_conf->voltage_max * 0.03 / LOAD_CURRENT_MAX && // max. 3% loss
bat_conf->current_cutoff_CV < (bat_conf->nominal_capacity / 10.0) && // C/10 or lower allowed
bat_conf->current_cutoff_CV > 0.01 &&
(bat_conf->trickle_enabled == false ||
@@ -150,6 +161,7 @@ bool battery_conf_check(battery_conf_t *bat_conf)
bat_conf->voltage_trickle > bat_conf->voltage_load_disconnect))
);
}
void battery_conf_overwrite(battery_conf_t *source, battery_conf_t *destination, battery_state_t *bat_state)
{
// TODO: stop DC/DC
@@ -166,6 +178,8 @@ void battery_conf_overwrite(battery_conf_t *source, battery_conf_t *destination,
destination->voltage_trickle = source->voltage_trickle;
destination->time_trickle_recharge = source->time_trickle_recharge;
destination->temperature_compensation = source->temperature_compensation;
destination->internal_resistance = source->internal_resistance;
destination->wire_resistance = source->wire_resistance;
// reset Ah counter and SOH if battery nominal capacity was changed
if (destination->nominal_capacity != source->nominal_capacity) {