USB charging output control via LoadOutput class
- Introduce new CONFIG_HAS_USB_PWR_OUTPUT - Improve charger.discharge_control function - Add battery empty flag
This commit is contained in:
@@ -227,11 +227,8 @@ void stop_discharge_at_low_voltage()
|
||||
charger.discharge_control(&bat_conf);
|
||||
TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit);
|
||||
|
||||
bat_terminal.bus->voltage = bat_conf.voltage_load_disconnect - 0.1;
|
||||
bat_terminal.bus->voltage = bat_conf.voltage_absolute_min - 0.1;
|
||||
charger.discharge_control(&bat_conf);
|
||||
charger.discharge_control(&bat_conf); // 2s: still on
|
||||
TEST_ASSERT_NOT_EQUAL(0, bat_terminal.neg_current_limit);
|
||||
charger.discharge_control(&bat_conf); // 3s: off
|
||||
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
|
||||
}
|
||||
|
||||
@@ -260,19 +257,17 @@ void restart_discharge_if_allowed()
|
||||
init_structs();
|
||||
|
||||
// stop because of undervoltage
|
||||
bat_terminal.bus->voltage = bat_conf.voltage_load_disconnect - 0.1;
|
||||
charger.discharge_control(&bat_conf);
|
||||
charger.discharge_control(&bat_conf);
|
||||
charger.discharge_control(&bat_conf); // 3s debounce
|
||||
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
|
||||
|
||||
// increase voltage slightly above DISconnect voltage
|
||||
bat_terminal.bus->voltage = bat_conf.voltage_load_disconnect + 0.1;
|
||||
bat_terminal.bus->voltage = bat_conf.voltage_absolute_min - 0.1;
|
||||
charger.discharge_control(&bat_conf);
|
||||
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
|
||||
|
||||
// increase voltage above REconnect voltage
|
||||
bat_terminal.bus->voltage = bat_conf.voltage_load_reconnect + 0.1;
|
||||
// increase voltage slightly above absolute minimum
|
||||
bat_terminal.bus->voltage = bat_conf.voltage_absolute_min + 0.05;
|
||||
charger.discharge_control(&bat_conf);
|
||||
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
|
||||
|
||||
// increase voltage above hysteresis voltage
|
||||
bat_terminal.bus->voltage = bat_conf.voltage_absolute_min + 0.15;
|
||||
charger.discharge_control(&bat_conf);
|
||||
TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit);
|
||||
}
|
||||
|
||||
+1
-1
@@ -94,7 +94,7 @@ void adc_alert_undervoltage_triggering()
|
||||
daq_update();
|
||||
|
||||
charger.discharge_control(&bat_conf);
|
||||
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_UNDERVOLTAGE));
|
||||
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_UNDERVOLTAGE)); // ToDo
|
||||
}
|
||||
|
||||
void adc_alert_overvoltage_triggering()
|
||||
|
||||
Reference in New Issue
Block a user