USB charging output control via LoadOutput class
- Introduce new CONFIG_HAS_USB_PWR_OUTPUT - Improve charger.discharge_control function - Add battery empty flag
This commit is contained in:
+54
-37
@@ -15,6 +15,7 @@
|
||||
#include "device_status.h"
|
||||
|
||||
extern DeviceStatus dev_stat;
|
||||
extern LoadOutput load;
|
||||
|
||||
void battery_conf_init(BatConf *bat, BatType type, int num_cells, float nominal_capacity)
|
||||
{
|
||||
@@ -242,7 +243,8 @@ bool battery_conf_changed(BatConf *a, BatConf *b)
|
||||
void Charger::detect_num_batteries(BatConf *bat)
|
||||
{
|
||||
if (port->bus->voltage > bat->voltage_absolute_min * 2 &&
|
||||
port->bus->voltage < bat->voltage_absolute_max * 2) {
|
||||
port->bus->voltage < bat->voltage_absolute_max * 2)
|
||||
{
|
||||
port->bus->series_multiplier = 2;
|
||||
printf("Detected two batteries (total %.2f V max)\n", bat->topping_voltage * 2);
|
||||
}
|
||||
@@ -289,38 +291,45 @@ void Charger::enter_state(int next_state)
|
||||
|
||||
void Charger::discharge_control(BatConf *bat_conf)
|
||||
{
|
||||
// load output state is defined by battery negative current limit
|
||||
if (port->neg_current_limit < 0) {
|
||||
// discharging currently allowed. see if that's still valid:
|
||||
if (port->bus->voltage <
|
||||
port->bus->src_control_voltage(bat_conf->voltage_load_disconnect))
|
||||
{
|
||||
uv_debounce_counter++;
|
||||
if (uv_debounce_counter >= 3) { // 3s in undervoltage --> switch off
|
||||
// low state of charge
|
||||
port->neg_current_limit = 0;
|
||||
num_deep_discharges++;
|
||||
dev_stat.set_error(ERR_BAT_UNDERVOLTAGE);
|
||||
if (!empty) {
|
||||
// as we don't have a proper SOC estimation, we determine an empty battery by the main
|
||||
// load output being switched off
|
||||
if (flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
|
||||
empty = true;
|
||||
num_deep_discharges++;
|
||||
dev_stat.set_error(ERR_BAT_UNDERVOLTAGE);
|
||||
|
||||
if (usable_capacity == 0.0F) {
|
||||
// reset to measured value if discharged the first time
|
||||
usable_capacity = discharged_Ah;
|
||||
}
|
||||
else {
|
||||
// slowly adapt new measurements with low-pass filter
|
||||
usable_capacity =
|
||||
0.8 * usable_capacity +
|
||||
0.2 * discharged_Ah;
|
||||
}
|
||||
|
||||
// simple SOH estimation
|
||||
soh = usable_capacity / bat_conf->nominal_capacity;
|
||||
if (usable_capacity == 0.0F) {
|
||||
// reset to measured value if discharged the first time
|
||||
usable_capacity = discharged_Ah;
|
||||
}
|
||||
else {
|
||||
// slowly adapt new measurements with low-pass filter
|
||||
usable_capacity =
|
||||
0.8 * usable_capacity +
|
||||
0.2 * discharged_Ah;
|
||||
}
|
||||
}
|
||||
else {
|
||||
uv_debounce_counter = 0;
|
||||
}
|
||||
|
||||
// simple SOH estimation
|
||||
soh = usable_capacity / bat_conf->nominal_capacity;
|
||||
}
|
||||
}
|
||||
else {
|
||||
if (!flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
|
||||
empty = false;
|
||||
}
|
||||
}
|
||||
|
||||
// negative current limit = allowed battery discharge current
|
||||
if (port->neg_current_limit < 0) {
|
||||
|
||||
// This limit should normally never be reached, as the load output settings should be
|
||||
// higher. The flag can be used to trigger actions of last resort, e.g. deep-sleep
|
||||
// of the charge controller itself.
|
||||
if (port->bus->voltage < port->bus->src_control_voltage(bat_conf->voltage_absolute_min)) {
|
||||
port->neg_current_limit = 0;
|
||||
dev_stat.set_error(ERR_BAT_UNDERVOLTAGE);
|
||||
}
|
||||
|
||||
if (bat_temperature > bat_conf->discharge_temp_max) {
|
||||
port->neg_current_limit = 0;
|
||||
@@ -333,18 +342,26 @@ void Charger::discharge_control(BatConf *bat_conf)
|
||||
}
|
||||
else {
|
||||
// discharging currently not allowed. should we allow it?
|
||||
if (port->bus->voltage >= port->bus->src_control_voltage(bat_conf->voltage_load_reconnect)
|
||||
&& bat_temperature < bat_conf->discharge_temp_max - 1
|
||||
&& bat_temperature > bat_conf->discharge_temp_min + 1)
|
||||
|
||||
if (port->bus->voltage >=
|
||||
port->bus->src_control_voltage(bat_conf->voltage_absolute_min + 0.1))
|
||||
{
|
||||
dev_stat.clear_error(ERR_BAT_UNDERVOLTAGE);
|
||||
}
|
||||
|
||||
if (bat_temperature < bat_conf->discharge_temp_max - 1 &&
|
||||
bat_temperature > bat_conf->discharge_temp_min + 1)
|
||||
{
|
||||
dev_stat.clear_error(ERR_BAT_DIS_OVERTEMP | ERR_BAT_DIS_UNDERTEMP);
|
||||
}
|
||||
|
||||
if (!dev_stat.has_error(
|
||||
ERR_BAT_UNDERVOLTAGE | ERR_BAT_DIS_OVERTEMP | ERR_BAT_DIS_UNDERTEMP))
|
||||
{
|
||||
// discharge current is stored as absolute value in bat_conf, but defined
|
||||
// as negative current for power port
|
||||
port->neg_current_limit = -bat_conf->discharge_current_max;
|
||||
|
||||
// delete all discharge error flags
|
||||
dev_stat.clear_error(ERR_BAT_DIS_OVERTEMP);
|
||||
dev_stat.clear_error(ERR_BAT_DIS_UNDERTEMP);
|
||||
dev_stat.clear_error(ERR_BAT_UNDERVOLTAGE);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||