Rename some charger variables
- Float charging is the more correct and more commonly used term compared to trickle charging - Putting voltage at the end of some variable names for more consistency
This commit is contained in:
+4
-4
@@ -95,12 +95,12 @@ void adc_alert_lv_undervoltage_triggering()
|
||||
{
|
||||
dev_stat.clear_error(ERR_ANY_ERROR);
|
||||
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
|
||||
daq_set_lv_limits(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min);
|
||||
daq_set_lv_limits(bat_conf.absolute_max_voltage, bat_conf.absolute_min_voltage);
|
||||
prepare_adc_filtered();
|
||||
adc_update_value(ADC_POS(v_low));
|
||||
|
||||
// undervoltage test
|
||||
adcval.battery_voltage = bat_conf.voltage_absolute_min - 0.1;
|
||||
adcval.battery_voltage = bat_conf.absolute_min_voltage - 0.1;
|
||||
prepare_adc_readings(adcval);
|
||||
adc_update_value(ADC_POS(v_low));
|
||||
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_LOAD_VOLTAGE_DIP));
|
||||
@@ -123,14 +123,14 @@ void adc_alert_lv_overvoltage_triggering()
|
||||
{
|
||||
dev_stat.clear_error(ERR_ANY_ERROR);
|
||||
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
|
||||
daq_set_lv_limits(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min);
|
||||
daq_set_lv_limits(bat_conf.absolute_max_voltage, bat_conf.absolute_min_voltage);
|
||||
prepare_adc_filtered();
|
||||
adc_update_value(ADC_POS(v_low));
|
||||
|
||||
dcdc.state = DCDC_CONTROL_MPPT;
|
||||
|
||||
// overvoltage test
|
||||
adcval.battery_voltage = bat_conf.voltage_absolute_max + 0.1;
|
||||
adcval.battery_voltage = bat_conf.absolute_max_voltage + 0.1;
|
||||
prepare_adc_readings(adcval);
|
||||
adc_update_value(ADC_POS(v_low));
|
||||
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_OVERVOLTAGE));
|
||||
|
||||
Reference in New Issue
Block a user