Fix load overvoltage limit
The setting is now based on LoadOutput menber overvoltage and not on the bus voltage bounds, which are used for charging setpoint.
This commit is contained in:
committed by
Martin Jäger
parent
68e0336279
commit
cdb9183c11
+3
-3
@@ -261,7 +261,7 @@ void control_off_overvoltage_to_on_at_lower_voltage()
|
||||
load_init(&load_out);
|
||||
load_out.state = LOAD_STATE_OFF_OVERVOLTAGE;
|
||||
load_out.usb_state = LOAD_STATE_ON;
|
||||
port.bus->voltage = port.bus->sink_voltage_bound + 0.1;
|
||||
port.bus->voltage = load_out.overvoltage + 0.1;
|
||||
dev_stat.error_flags = ERR_LOAD_OVERVOLTAGE;
|
||||
|
||||
load_out.control();
|
||||
@@ -269,12 +269,12 @@ void control_off_overvoltage_to_on_at_lower_voltage()
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load_out.state);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load_out.usb_state); // not affected by overvoltage
|
||||
|
||||
port.bus->voltage = port.bus->sink_voltage_bound - 0.1; // test hysteresis
|
||||
port.bus->voltage = load_out.overvoltage - 0.1; // test hysteresis
|
||||
load_out.control();
|
||||
TEST_ASSERT_EQUAL(ERR_LOAD_OVERVOLTAGE, dev_stat.error_flags);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load_out.state);
|
||||
|
||||
port.bus->voltage = port.bus->sink_voltage_bound - load_out.ov_hysteresis - 0.1;
|
||||
port.bus->voltage = load_out.overvoltage - load_out.ov_hysteresis - 0.1;
|
||||
load_out.control();
|
||||
TEST_ASSERT_EQUAL(0, dev_stat.error_flags);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load_out.state); // deprecated
|
||||
|
||||