Fix load overvoltage limit
The setting is now based on LoadOutput menber overvoltage and not on the bus voltage bounds, which are used for charging setpoint.
This commit is contained in:
committed by
Martin Jäger
parent
68e0336279
commit
cdb9183c11
+2
-2
@@ -141,7 +141,7 @@ void LoadOutput::control()
|
||||
|
||||
// long-term overvoltage (overvoltage transients are detected as an ADC alert and switch
|
||||
// off the solar input instead of the load output)
|
||||
if (port->bus->voltage > port->bus->sink_voltage_bound ||
|
||||
if (port->bus->voltage > overvoltage ||
|
||||
port->bus->voltage > LOW_SIDE_VOLTAGE_MAX)
|
||||
{
|
||||
ov_debounce_counter++;
|
||||
@@ -180,7 +180,7 @@ void LoadOutput::control()
|
||||
}
|
||||
|
||||
if (dev_stat.has_error(ERR_LOAD_OVERVOLTAGE) &&
|
||||
port->bus->voltage < (port->bus->sink_voltage_bound - ov_hysteresis) &&
|
||||
port->bus->voltage < (overvoltage - ov_hysteresis) &&
|
||||
port->bus->voltage < (LOW_SIDE_VOLTAGE_MAX - ov_hysteresis))
|
||||
{
|
||||
dev_stat.clear_error(ERR_LOAD_OVERVOLTAGE);
|
||||
|
||||