Temperature compensation for charging target voltage added
This commit is contained in:
@@ -40,6 +40,11 @@ void battery_conf_init(battery_conf_t *bat, bat_type type, int num_cells, float
|
||||
bat->time_limit_recharge = 60; // sec
|
||||
bat->time_limit_CV = 120*60; // sec
|
||||
|
||||
bat->charge_temp_max = 50;
|
||||
bat->charge_temp_min = -10;
|
||||
bat->discharge_temp_max = 50;
|
||||
bat->discharge_temp_min = -10;
|
||||
|
||||
switch (type)
|
||||
{
|
||||
case BAT_TYPE_FLOODED:
|
||||
@@ -97,6 +102,7 @@ void battery_conf_init(battery_conf_t *bat, bat_type type, int num_cells, float
|
||||
bat->trickle_enabled = false;
|
||||
bat->equalization_enabled = false;
|
||||
bat->temperature_compensation = 0.0;
|
||||
bat->charge_temp_min = 0;
|
||||
break;
|
||||
|
||||
case BAT_TYPE_NMC:
|
||||
@@ -118,6 +124,7 @@ void battery_conf_init(battery_conf_t *bat, bat_type type, int num_cells, float
|
||||
bat->trickle_enabled = false;
|
||||
bat->equalization_enabled = false;
|
||||
bat->temperature_compensation = 0.0;
|
||||
bat->charge_temp_min = 0;
|
||||
break;
|
||||
|
||||
case BAT_TYPE_NONE:
|
||||
@@ -177,6 +184,10 @@ void battery_conf_overwrite(battery_conf_t *source, battery_conf_t *destination,
|
||||
destination->trickle_enabled = source->trickle_enabled;
|
||||
destination->voltage_trickle = source->voltage_trickle;
|
||||
destination->time_trickle_recharge = source->time_trickle_recharge;
|
||||
destination->charge_temp_max = source->charge_temp_max;
|
||||
destination->charge_temp_min = source->charge_temp_min;
|
||||
destination->discharge_temp_max = source->discharge_temp_max;
|
||||
destination->discharge_temp_min = source->discharge_temp_min;
|
||||
destination->temperature_compensation = source->temperature_compensation;
|
||||
destination->internal_resistance = source->internal_resistance;
|
||||
destination->wire_resistance = source->wire_resistance;
|
||||
|
||||
Reference in New Issue