Fixing load output and improved overvoltage config
Previous load output expected the battery port as a parameter and checked if discharging of the battery was allowed. New implementation has own load port and needs to check if current output (i.e. positive direction) is allowed. Overvoltage setting is now configured via power port sink_voltage_max.
This commit is contained in:
+16
-19
@@ -20,7 +20,6 @@
|
||||
#include "hardware.h"
|
||||
#include "leds.h"
|
||||
#include "log.h"
|
||||
#include <time.h>
|
||||
|
||||
volatile bool short_circuit = false;
|
||||
|
||||
@@ -193,8 +192,8 @@ LoadOutput::LoadOutput(PowerPort *pwr_port)
|
||||
{
|
||||
port = pwr_port;
|
||||
current_max = LOAD_CURRENT_MAX;
|
||||
enabled_target = true;
|
||||
usb_enabled_target = true;
|
||||
enable = true;
|
||||
usb_enable = true;
|
||||
switch_set(false);
|
||||
usb_set(false);
|
||||
switch_state = LOAD_STATE_DISABLED;
|
||||
@@ -209,7 +208,7 @@ void LoadOutput::usb_state_machine()
|
||||
{
|
||||
switch (usb_state) {
|
||||
case LOAD_STATE_DISABLED:
|
||||
if (usb_enabled_target == true) {
|
||||
if (usb_enable == true) {
|
||||
usb_set(true);
|
||||
usb_state = LOAD_STATE_ON;
|
||||
}
|
||||
@@ -224,7 +223,7 @@ void LoadOutput::usb_state_machine()
|
||||
usb_set(false);
|
||||
usb_state = LOAD_STATE_OFF_OVERCURRENT;
|
||||
}
|
||||
else if (usb_enabled_target == false) {
|
||||
else if (usb_enable == false) {
|
||||
usb_set(false);
|
||||
usb_state = LOAD_STATE_DISABLED;
|
||||
}
|
||||
@@ -232,7 +231,7 @@ void LoadOutput::usb_state_machine()
|
||||
case LOAD_STATE_OFF_LOW_SOC:
|
||||
// currently still same cut-off SOC limit as the load
|
||||
if (switch_state == LOAD_STATE_ON) {
|
||||
if (usb_enabled_target == true) {
|
||||
if (usb_enable == true) {
|
||||
usb_set(true);
|
||||
usb_state = LOAD_STATE_ON;
|
||||
}
|
||||
@@ -249,26 +248,22 @@ void LoadOutput::usb_state_machine()
|
||||
}
|
||||
}
|
||||
|
||||
static time_t lvd_timestamp = 0; // stores when the load was disconnected last time
|
||||
|
||||
void LoadOutput::state_machine()
|
||||
{
|
||||
//printf("Load State: %d\n", switch_state);
|
||||
switch (switch_state) {
|
||||
case LOAD_STATE_DISABLED:
|
||||
if (port->neg_current_limit < 0 // discharging enabled
|
||||
&& enabled_target == true)
|
||||
{
|
||||
if (enable == true && port->pos_current_limit > 0) {
|
||||
switch_set(true);
|
||||
switch_state = LOAD_STATE_ON;
|
||||
}
|
||||
break;
|
||||
case LOAD_STATE_ON:
|
||||
if (enabled_target == false) {
|
||||
if (enable == false) {
|
||||
switch_set(false);
|
||||
switch_state = LOAD_STATE_DISABLED;
|
||||
}
|
||||
else if (port->neg_current_limit == 0) { // float == is allowed for 0.0
|
||||
else if (port->pos_current_limit == 0) { // float == is allowed for 0.0
|
||||
lvd_timestamp = time(NULL);
|
||||
switch_set(false);
|
||||
switch_state = LOAD_STATE_OFF_LOW_SOC;
|
||||
@@ -276,10 +271,10 @@ void LoadOutput::state_machine()
|
||||
break;
|
||||
case LOAD_STATE_OFF_LOW_SOC:
|
||||
// wait at least one hour
|
||||
if (port->neg_current_limit < 0 // discharging enabled again
|
||||
if (port->pos_current_limit > 0
|
||||
&& time(NULL) - lvd_timestamp > 60*60)
|
||||
{
|
||||
if (enabled_target == true) {
|
||||
if (enable == true) {
|
||||
switch_set(true);
|
||||
switch_state = LOAD_STATE_ON;
|
||||
}
|
||||
@@ -295,13 +290,15 @@ void LoadOutput::state_machine()
|
||||
}
|
||||
break;
|
||||
case LOAD_STATE_OFF_OVERVOLTAGE:
|
||||
if (port->voltage < LOW_SIDE_VOLTAGE_MAX) { // TODO: add hysteresis?
|
||||
if (port->voltage < port->sink_voltage_max &&
|
||||
port->voltage < LOW_SIDE_VOLTAGE_MAX)
|
||||
{
|
||||
switch_state = LOAD_STATE_DISABLED; // switch to normal mode again
|
||||
}
|
||||
break;
|
||||
case LOAD_STATE_OFF_SHORT_CIRCUIT:
|
||||
// stay here until the charge controller is reset or load is switched off remotely
|
||||
if (enabled_target == false) {
|
||||
if (enable == false) {
|
||||
short_circuit = false;
|
||||
switch_state = LOAD_STATE_DISABLED; // switch to normal mode again
|
||||
}
|
||||
@@ -312,7 +309,7 @@ void LoadOutput::state_machine()
|
||||
}
|
||||
|
||||
// this function is called more often than the state machine
|
||||
void LoadOutput::control(float load_max_voltage)
|
||||
void LoadOutput::control()
|
||||
{
|
||||
if (short_circuit) {
|
||||
switch_state = LOAD_STATE_OFF_SHORT_CIRCUIT;
|
||||
@@ -334,7 +331,7 @@ void LoadOutput::control(float load_max_voltage)
|
||||
}
|
||||
|
||||
static int debounce_counter = 0;
|
||||
if (port->voltage > load_max_voltage ||
|
||||
if (port->voltage > port->sink_voltage_max ||
|
||||
port->voltage > LOW_SIDE_VOLTAGE_MAX)
|
||||
{
|
||||
debounce_counter++;
|
||||
|
||||
Reference in New Issue