Energy calculation for PWM CC fixed
- Correct negative sign for incoming solar current - Current multiplied with PWM duty cycle to get average current - Min/max calculation moved to log.cpp
This commit is contained in:
+9
-3
@@ -1,5 +1,5 @@
|
||||
/* LibreSolar MPPT charge controller firmware
|
||||
* Copyright (c) 2016-2018 Martin Jäger (www.libre.solar)
|
||||
/* LibreSolar charge controller firmware
|
||||
* Copyright (c) 2016-2019 Martin Jäger (www.libre.solar)
|
||||
*
|
||||
* Licensed under the Apache License, Version 2.0 (the "License");
|
||||
* you may not use this file except in compliance with the License.
|
||||
@@ -16,6 +16,11 @@
|
||||
|
||||
#ifndef UNIT_TEST
|
||||
|
||||
/** @file
|
||||
*
|
||||
* @brief Entry point of charge controller firmware
|
||||
*/
|
||||
|
||||
#include "mbed.h"
|
||||
|
||||
#include "thingset.h" // handles access to internal data via communication interfaces
|
||||
@@ -86,7 +91,8 @@ void system_control()
|
||||
dc_bus_energy_balance(&hs_bus);
|
||||
dc_bus_energy_balance(&ls_bus);
|
||||
dc_bus_energy_balance(&load_bus);
|
||||
log_update_energy(&log_data, &ls_bus, &hs_bus, &load_bus);
|
||||
log_update_energy(&log_data, &hs_bus, &ls_bus, &load_bus);
|
||||
log_update_min_max_values(&log_data, &dcdc, &bat_state, &load, &hs_bus, &ls_bus, &load_bus);
|
||||
battery_update_soc(&bat_conf, &bat_state, bat_bus->voltage, bat_bus->current);
|
||||
}
|
||||
counter++;
|
||||
|
||||