Energy calculation for PWM CC fixed

- Correct negative sign for incoming solar current
- Current multiplied with PWM duty cycle to get average current
- Min/max calculation moved to log.cpp
This commit is contained in:
Martin Jaeger
2019-05-15 11:06:49 +02:00
parent 05ccfb4c65
commit b742fe6671
7 changed files with 99 additions and 79 deletions
+1 -1
View File
@@ -158,7 +158,7 @@ bool battery_conf_check(battery_conf_t *bat_conf)
*/
return
(bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.6) &&
(bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.4) &&
bat_conf->voltage_recharge < (bat_conf->voltage_topping - 0.4) &&
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1) &&
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4) &&