NTC on PCB not used as battery temperature anymore
- MCU temperature was renamed to internal_temperature - NTC at board edge senses temperatures far above battery / ambient temperature at high loads and is now ignored - Battery temperature always assumed 25ÂC unless external sensor is detected
This commit is contained in:
+2
-2
@@ -106,11 +106,11 @@ void log_new_bat_temp_max()
|
||||
TEST_ASSERT_EQUAL(45, log_data.bat_temp_max);
|
||||
}
|
||||
|
||||
extern float mcu_temp;
|
||||
extern float internal_temp;
|
||||
|
||||
void log_new_int_temp_max()
|
||||
{
|
||||
mcu_temp = 22;
|
||||
internal_temp = 22;
|
||||
log_update_min_max_values(&log_data);
|
||||
TEST_ASSERT_EQUAL(22, log_data.int_temp_max);
|
||||
}
|
||||
|
||||