DAQ: Add HV bus voltage_filtered

This commit is contained in:
Martin Jäger
2021-06-01 17:48:43 +02:00
parent 9765798944
commit a4760ebcb8
+10
View File
@@ -24,6 +24,7 @@ LOG_MODULE_REGISTER(daq, CONFIG_DAQ_LOG_LEVEL);
// filter parameter c for additional battery voltage and current low-pass filter
// c = dt / (tau + dt) = 0.1s / (10s + 0.1s)
#define HV_BUS_VOLTAGE_FILTER_CONST 0.0099F
#define LV_BUS_VOLTAGE_FILTER_CONST 0.0099F
#define LV_TERMINAL_CURRENT_FILTER_CONST 0.0099F
#define PWM_CURRENT_FILTER_CONST 0.0625F // 1.5 seconds
@@ -185,6 +186,15 @@ void daq_update()
#if BOARD_HAS_DCDC
hv_bus.voltage = adc_scaled(ADC_POS(v_high), vref, ADC_GAIN(v_high));
if (hv_bus.voltage_filtered != 0.0F) {
hv_bus.voltage_filtered = HV_BUS_VOLTAGE_FILTER_CONST * hv_bus.voltage +
(1.0F - HV_BUS_VOLTAGE_FILTER_CONST) * hv_bus.voltage_filtered;
}
else {
// initialize properly at startup
hv_bus.voltage_filtered = hv_bus.voltage;
}
#endif
#if BOARD_HAS_PWM_PORT