tests: app: migrate unit tests from Unity to ztest

Convert the application unit tests to ztest, so that all tests can be
run with twister and the Unity module is not required anymore.

Each test file becomes a ztest suite. The test names got the prefix
test_ as required by twister. Unity assertions were converted as
follows:

- TEST_ASSERT_EQUAL_FLOAT is replaced by assert_float_equal, which uses
  the same relative precision of 1e-5 as Unity.
- TEST_ASSERT_EQUAL and other integer assertions are replaced by their
  ztest equivalents. Unity compared these as integers, so float values
  were truncated before. All tests still pass with exact comparison.

In contrast to Unity, ztest runs the tests of a suite in alphabetical
order. The setup code for the DAQ tests is moved into a before function
and the half bridge is stopped before each buck converter test (same as
for the boost converter tests), as the buck tests previously relied on
running before the boost tests.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
Martin Jäger
2026-10-21 13:40:14 +02:00
co-authored by Claude Opus 5.5
parent a3f888fd79
commit a1fff4ee6f
11 changed files with 335 additions and 541 deletions
+46 -61
View File
@@ -14,36 +14,36 @@
static AdcValues adcval;
void test_adc_voltage_to_raw()
ZTEST(daq, test_adc_voltage_to_raw)
{
int32_t raw;
raw = adc_voltage_to_raw(0.0, 3300);
TEST_ASSERT_EQUAL_INT32(0, raw);
zassert_equal(raw, 0);
raw = adc_voltage_to_raw(3.3, 3300);
TEST_ASSERT_EQUAL_INT32(65535, raw);
zassert_equal(raw, 65535);
raw = adc_voltage_to_raw(1.65, 3300);
TEST_ASSERT_EQUAL_INT32(32767, raw);
zassert_equal(raw, 32767);
}
void test_adc_raw_to_voltage()
ZTEST(daq, test_adc_raw_to_voltage)
{
float voltage;
voltage = adc_raw_to_voltage(0, 3300);
TEST_ASSERT_EQUAL_FLOAT(0.0, voltage);
assert_float_equal(voltage, 0.0);
voltage = adc_raw_to_voltage(65535, 3300);
TEST_ASSERT_FLOAT_WITHIN(0.01, 3.3, voltage);
zassert_within(voltage, 3.3F, 0.01F);
voltage = adc_raw_to_voltage(32767, 3300);
TEST_ASSERT_FLOAT_WITHIN(0.01, 1.65, voltage);
zassert_within(voltage, 1.65F, 0.01F);
}
// testing only for 2 values
void check_filtering()
ZTEST(daq, test_check_filtering)
{
// reset values
clear_adc_filtered();
@@ -62,36 +62,36 @@ void check_filtering()
// overwrite filtered values
prepare_adc_filtered();
TEST_ASSERT_EQUAL(get_adc_filtered(ADC_POS(vref_mcu)), adc_filtered_bak[ADC_POS(vref_mcu)]);
TEST_ASSERT_EQUAL(get_adc_filtered(ADC_POS(v_high)), adc_filtered_bak[ADC_POS(v_high)]);
zassert_equal(adc_filtered_bak[ADC_POS(vref_mcu)], get_adc_filtered(ADC_POS(vref_mcu)));
zassert_equal(adc_filtered_bak[ADC_POS(v_high)], get_adc_filtered(ADC_POS(v_high)));
}
void check_solar_terminal_readings()
ZTEST(daq, test_check_solar_terminal_readings)
{
TEST_ASSERT_EQUAL_FLOAT(adcval.solar_voltage, round(hv_terminal.bus->voltage * 10) / 10);
TEST_ASSERT_EQUAL_FLOAT(adcval.dcdc_current / adcval.solar_voltage * adcval.battery_voltage,
-round(hv_terminal.current * 10) / 10);
assert_float_equal(round(hv_terminal.bus->voltage * 10) / 10, adcval.solar_voltage);
assert_float_equal(-round(hv_terminal.current * 10) / 10,
adcval.dcdc_current / adcval.solar_voltage * adcval.battery_voltage);
}
void check_bat_terminal_readings()
ZTEST(daq, test_check_bat_terminal_readings)
{
TEST_ASSERT_EQUAL_FLOAT(adcval.battery_voltage, round(lv_terminal.bus->voltage * 10) / 10);
TEST_ASSERT_EQUAL_FLOAT(adcval.dcdc_current - adcval.load_current,
round(lv_terminal.current * 10) / 10);
assert_float_equal(round(lv_terminal.bus->voltage * 10) / 10, adcval.battery_voltage);
assert_float_equal(round(lv_terminal.current * 10) / 10,
adcval.dcdc_current - adcval.load_current);
}
void check_load_terminal_readings()
ZTEST(daq, test_check_load_terminal_readings)
{
TEST_ASSERT_EQUAL_FLOAT(adcval.battery_voltage, round(load.bus->voltage * 10) / 10);
TEST_ASSERT_EQUAL_FLOAT(adcval.load_current, round(load.current * 10) / 10);
assert_float_equal(round(load.bus->voltage * 10) / 10, adcval.battery_voltage);
assert_float_equal(round(load.current * 10) / 10, adcval.load_current);
}
void check_temperature_readings()
{
TEST_ASSERT_EQUAL_FLOAT(adcval.bat_temperature, round(charger.bat_temperature * 10) / 10);
assert_float_equal(round(charger.bat_temperature * 10) / 10, adcval.bat_temperature);
}
void adc_alert_lv_undervoltage_triggering()
ZTEST(daq, test_adc_alert_lv_undervoltage_triggering)
{
dev_stat.clear_error(ERR_ANY_ERROR);
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
@@ -103,11 +103,11 @@ void adc_alert_lv_undervoltage_triggering()
adcval.battery_voltage = bat_conf.absolute_min_voltage - 0.1f;
prepare_adc_readings(adcval);
adc_update_value(ADC_POS(v_low));
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_LOAD_VOLTAGE_DIP));
zassert_equal(dev_stat.has_error(ERR_LOAD_VOLTAGE_DIP), false);
adc_update_value(ADC_POS(v_low));
load.control();
TEST_ASSERT_EQUAL(true, flags_check(&load.error_flags, ERR_LOAD_VOLTAGE_DIP));
TEST_ASSERT_EQUAL(LOAD_STATE_OFF, load.state);
zassert_equal(flags_check(&load.error_flags, ERR_LOAD_VOLTAGE_DIP), true);
zassert_equal(load.state, LOAD_STATE_OFF);
// reset values
adcval.battery_voltage = 13;
@@ -116,10 +116,10 @@ void adc_alert_lv_undervoltage_triggering()
daq_update();
charger.discharge_control(&bat_conf);
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_UNDERVOLTAGE)); // ToDo
zassert_equal(dev_stat.has_error(ERR_BAT_UNDERVOLTAGE), false); // ToDo
}
void adc_alert_lv_overvoltage_triggering()
ZTEST(daq, test_adc_alert_lv_overvoltage_triggering)
{
dev_stat.clear_error(ERR_ANY_ERROR);
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
@@ -133,11 +133,11 @@ void adc_alert_lv_overvoltage_triggering()
adcval.battery_voltage = bat_conf.absolute_max_voltage + 0.1f;
prepare_adc_readings(adcval);
adc_update_value(ADC_POS(v_low));
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_OVERVOLTAGE));
zassert_equal(dev_stat.has_error(ERR_BAT_OVERVOLTAGE), false);
adc_update_value(ADC_POS(v_low));
TEST_ASSERT_EQUAL(true, dev_stat.has_error(ERR_BAT_OVERVOLTAGE));
// TEST_ASSERT_EQUAL(false, pwm_switch.active());
TEST_ASSERT_EQUAL(DCDC_CONTROL_OFF, dcdc.state);
zassert_equal(dev_stat.has_error(ERR_BAT_OVERVOLTAGE), true);
// zassert_equal(pwm_switch.active(), false);
zassert_equal(dcdc.state, DCDC_CONTROL_OFF);
// reset values
adcval.battery_voltage = 12;
@@ -147,10 +147,10 @@ void adc_alert_lv_overvoltage_triggering()
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_OVERVOLTAGE));
zassert_equal(dev_stat.has_error(ERR_BAT_OVERVOLTAGE), false);
}
void adc_alert_hv_overvoltage_triggering()
ZTEST(daq, test_adc_alert_hv_overvoltage_triggering)
{
dev_stat.clear_error(ERR_ANY_ERROR);
daq_set_hv_limit(DT_PROP(DT_PATH(pcb), hs_voltage_max));
@@ -161,17 +161,17 @@ void adc_alert_hv_overvoltage_triggering()
adcval.solar_voltage = 85.0F;
prepare_adc_readings(adcval);
adc_update_value(ADC_POS(v_high));
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_DCDC_HS_OVERVOLTAGE));
zassert_equal(dev_stat.has_error(ERR_DCDC_HS_OVERVOLTAGE), false);
adc_update_value(ADC_POS(v_high));
TEST_ASSERT_EQUAL(true, dev_stat.has_error(ERR_DCDC_HS_OVERVOLTAGE));
TEST_ASSERT_EQUAL(DCDC_CONTROL_OFF, dcdc.state);
zassert_equal(dev_stat.has_error(ERR_DCDC_HS_OVERVOLTAGE), true);
zassert_equal(dcdc.state, DCDC_CONTROL_OFF);
}
void adc_alert_overflow_prevention()
ZTEST(daq, test_adc_alert_overflow_prevention)
{
// try to set an alert that overflows the 12-bit ADC resolution
uint16_t limit = adc_raw_clamp(1, UINT16_MAX + 1);
TEST_ASSERT_EQUAL_HEX(UINT16_MAX, limit);
zassert_equal(limit, UINT16_MAX);
}
/** Data acquisition tests
@@ -179,8 +179,10 @@ void adc_alert_overflow_prevention()
* Purpose: Check if raw data from 2 voltage and 2 current measurements are converted
* to calculated voltage/current measurements of different DC buses
*/
int daq_tests()
static void daq_before(void *fixture)
{
ARG_UNUSED(fixture);
adcval.bat_temperature = 25;
adcval.battery_voltage = 12;
adcval.dcdc_current = 3;
@@ -188,27 +190,10 @@ int daq_tests()
adcval.load_current = 1;
adcval.solar_voltage = 30;
prepare_adc_readings(adcval);
UNITY_BEGIN();
RUN_TEST(test_adc_voltage_to_raw);
RUN_TEST(test_adc_raw_to_voltage);
RUN_TEST(check_filtering);
prepare_adc_filtered();
// call original daq_update function
daq_update();
RUN_TEST(check_solar_terminal_readings);
RUN_TEST(check_bat_terminal_readings);
RUN_TEST(check_load_terminal_readings);
// RUN_TEST(check_temperature_readings); // TODO
RUN_TEST(adc_alert_lv_undervoltage_triggering);
RUN_TEST(adc_alert_lv_overvoltage_triggering);
RUN_TEST(adc_alert_hv_overvoltage_triggering);
RUN_TEST(adc_alert_overflow_prevention);
return UNITY_END();
}
ZTEST_SUITE(daq, NULL, NULL, daq_before, NULL, NULL);