Fix DC/DC start check for 24V batteries (#95)
This commit is contained in:
+5
-5
@@ -102,7 +102,7 @@ int Dcdc::duty_cycle_delta()
|
||||
state = DCDC_STATE_DERATING;
|
||||
pwr_inc_goal = -1; // decrease output power
|
||||
}
|
||||
else if (out->power < output_power_min && out->bus->voltage < out->bus->src_voltage_bound) {
|
||||
else if (out->power < output_power_min && out->bus->voltage < out->bus->src_control_voltage()) {
|
||||
// no load condition (e.g. start-up of nanogrid) --> raise voltage
|
||||
pwr_inc_goal = 1; // increase output power
|
||||
}
|
||||
@@ -141,18 +141,18 @@ int Dcdc::check_start_conditions()
|
||||
}
|
||||
|
||||
if (lvs->bus->sink_current_margin > 0 &&
|
||||
lvs->bus->voltage < lvs->bus->sink_voltage_bound &&
|
||||
lvs->bus->voltage < lvs->bus->sink_control_voltage() &&
|
||||
hvs->bus->src_current_margin < 0 &&
|
||||
hvs->bus->voltage > hvs->bus->src_voltage_bound &&
|
||||
hvs->bus->voltage > hvs->bus->src_control_voltage() &&
|
||||
hvs->bus->voltage * 0.85 > lvs->bus->voltage)
|
||||
{
|
||||
return 1; // start in buck mode allowed
|
||||
}
|
||||
|
||||
if (hvs->bus->sink_current_margin > 0 &&
|
||||
hvs->bus->voltage < hvs->bus->sink_voltage_bound &&
|
||||
hvs->bus->voltage < hvs->bus->sink_control_voltage() &&
|
||||
lvs->bus->src_current_margin < 0 &&
|
||||
lvs->bus->voltage > lvs->bus->src_voltage_bound)
|
||||
lvs->bus->voltage > lvs->bus->src_control_voltage())
|
||||
{
|
||||
return -1; // start in boost mode allowed
|
||||
}
|
||||
|
||||