Fix DC/DC start check for 24V batteries (#95)

This commit is contained in:
Martin Jäger
2020-05-11 11:01:47 +02:00
parent faf19ee9e0
commit 9a5004e81d
2 changed files with 31 additions and 12 deletions
+5 -5
View File
@@ -102,7 +102,7 @@ int Dcdc::duty_cycle_delta()
state = DCDC_STATE_DERATING;
pwr_inc_goal = -1; // decrease output power
}
else if (out->power < output_power_min && out->bus->voltage < out->bus->src_voltage_bound) {
else if (out->power < output_power_min && out->bus->voltage < out->bus->src_control_voltage()) {
// no load condition (e.g. start-up of nanogrid) --> raise voltage
pwr_inc_goal = 1; // increase output power
}
@@ -141,18 +141,18 @@ int Dcdc::check_start_conditions()
}
if (lvs->bus->sink_current_margin > 0 &&
lvs->bus->voltage < lvs->bus->sink_voltage_bound &&
lvs->bus->voltage < lvs->bus->sink_control_voltage() &&
hvs->bus->src_current_margin < 0 &&
hvs->bus->voltage > hvs->bus->src_voltage_bound &&
hvs->bus->voltage > hvs->bus->src_control_voltage() &&
hvs->bus->voltage * 0.85 > lvs->bus->voltage)
{
return 1; // start in buck mode allowed
}
if (hvs->bus->sink_current_margin > 0 &&
hvs->bus->voltage < hvs->bus->sink_voltage_bound &&
hvs->bus->voltage < hvs->bus->sink_control_voltage() &&
lvs->bus->src_current_margin < 0 &&
lvs->bus->voltage > lvs->bus->src_voltage_bound)
lvs->bus->voltage > lvs->bus->src_control_voltage())
{
return -1; // start in boost mode allowed
}