Fixed basic nanogrid port implementation
Instead of SOLAR_TERMINAL, GRID_TERMINAL has to be defined in config.h (see also template).
This commit is contained in:
@@ -115,7 +115,9 @@ const data_object_t data_objects[] = {
|
||||
|
||||
// battery related data objects
|
||||
{0x70, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.voltage), "Bat_V"},
|
||||
#ifdef SOLAR_TERMINAL
|
||||
{0x71, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(solar_terminal.voltage), "Solar_V"},
|
||||
#endif
|
||||
{0x72, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.current), "Bat_A"},
|
||||
{0x73, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(load_terminal.current), "Load_A"},
|
||||
{0x74, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 1, (void*) &(charger.bat_temperature), "Bat_degC"},
|
||||
@@ -128,11 +130,15 @@ const data_object_t data_objects[] = {
|
||||
#if FEATURE_DCDC_CONVERTER
|
||||
{0x79, TS_OUTPUT, TS_READ_ALL, TS_T_UINT16, 0, (void*) &(dcdc.state), "DCDCState"},
|
||||
#endif
|
||||
#ifdef SOLAR_TERMINAL
|
||||
{0x7A, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(solar_terminal.current), "Solar_A"},
|
||||
#endif
|
||||
{0x7B, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.sink_voltage_max), "BatTarget_V"},
|
||||
{0x7C, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.pos_current_limit), "BatTarget_A"},
|
||||
{0x7D, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.power), "Bat_W"},
|
||||
#ifdef SOLAR_TERMINAL
|
||||
{0x7E, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(solar_terminal.power), "Solar_W"},
|
||||
#endif
|
||||
{0x7F, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(load_terminal.power), "Load_W"},
|
||||
|
||||
{0x90, TS_OUTPUT, TS_READ_ALL, TS_T_UINT32, 0, (void*) &(dev_stat.error_flags), "ErrorFlags"},
|
||||
@@ -151,7 +157,9 @@ const data_object_t data_objects[] = {
|
||||
{0x10, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_UINT16, 0, (void*) &(dev_stat.load_power_max_day), "LoadMaxDay_W"},
|
||||
|
||||
// accumulated data
|
||||
#ifdef SOLAR_TERMINAL
|
||||
{0xA0, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(solar_terminal.neg_energy_Wh), "SolarInDay_Wh"},
|
||||
#endif
|
||||
{0xA1, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(load_terminal.pos_energy_Wh), "LoadOutDay_Wh"},
|
||||
{0xA2, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(bat_terminal.pos_energy_Wh), "BatChgDay_Wh"},
|
||||
{0xA3, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(bat_terminal.neg_energy_Wh), "BatDisDay_Wh"},
|
||||
|
||||
Reference in New Issue