From 882f2813332a326d2cebf0f6ac6f8f0cc0b3f8a6 Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?Martin=20J=C3=A4ger?= Date: Mon, 11 May 2020 14:08:03 +0200 Subject: [PATCH] Fix undervoltage error flag reporting Load shedding should only trigger capacity calculation, but not set the undervoltage flag. That flag is only set for voltage below absolute min. --- src/bat_charger.cpp | 1 - 1 file changed, 1 deletion(-) diff --git a/src/bat_charger.cpp b/src/bat_charger.cpp index 3d1a927..8e0090c 100644 --- a/src/bat_charger.cpp +++ b/src/bat_charger.cpp @@ -309,7 +309,6 @@ void Charger::discharge_control(BatConf *bat_conf) if (flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) { empty = true; num_deep_discharges++; - dev_stat.set_error(ERR_BAT_UNDERVOLTAGE); if (usable_capacity == 0.0F) { // reset to measured value if discharged the first time