Fix Solar_V data object for PWM CCs

This commit is contained in:
Martin Jäger
2020-05-06 12:53:26 +02:00
parent a412117b5b
commit 8380b928df
2 changed files with 13 additions and 2 deletions
+9 -1
View File
@@ -42,7 +42,11 @@ void DeviceStatus::update_energy()
}
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR
if (solar_terminal.bus->voltage < bat_terminal.bus->voltage) {
#else
if (pwm_switch.ext_voltage < bat_terminal.bus->voltage) {
#endif
seconds_zero_solar += 1;
}
else {
@@ -82,10 +86,14 @@ void DeviceStatus::update_min_max_values()
battery_voltage_max = bat_terminal.bus->voltage;
}
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR
if (solar_terminal.bus->voltage > solar_voltage_max) {
solar_voltage_max = solar_terminal.bus->voltage;
}
#elif CONFIG_PWM_TERMINAL_SOLAR
if (pwm_switch.ext_voltage > solar_voltage_max) {
solar_voltage_max = pwm_switch.ext_voltage;
}
#endif
#if DT_COMPAT_DCDC