Fix load overvoltage control for 24V systems (#96)

This commit is contained in:
Martin Jäger
2020-05-21 10:09:54 +02:00
parent 882f281333
commit 81aefff168
3 changed files with 78 additions and 6 deletions
+62 -2
View File
@@ -26,12 +26,13 @@ static void load_drv_init()
output_on = false;
}
static void load_init(LoadOutput *l, bool on = false)
static void load_init(LoadOutput *l, bool on = false, int num_batteries = 1)
{
l->overvoltage = 14.6;
l->current = 0;
l->pos_current_limit = 10;
l->bus->voltage = 14;
l->bus->series_multiplier = num_batteries;
l->bus->voltage = 14 * num_batteries;
l->bus->sink_voltage_bound = 14.4;
l->bus->src_voltage_bound = 12;
l->bus->sink_current_margin = 10;
@@ -62,6 +63,18 @@ static void control_off_to_on_if_everything_fine()
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load_out.state);
}
static void control_off_to_on_if_everything_fine_dual_battery()
{
DcBus bus = {};
LoadOutput load_out(&bus, &load_drv_set, &load_drv_init);
load_init(&load_out, false, 2);
load_out.enable = true;
load_out.control();
TEST_ASSERT_EQUAL(0, load_out.error_flags);
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load_out.state);
}
static void control_on_to_off_shedding()
{
DcBus bus = {};
@@ -95,6 +108,27 @@ void control_on_to_off_overvoltage()
TEST_ASSERT_EQUAL(LOAD_STATE_OFF, load_out.state);
}
void control_on_to_off_overvoltage_dual_battery()
{
DcBus bus = {};
LoadOutput load_out(&bus, &load_drv_set, &load_drv_init);
load_init(&load_out, true, 2);
bus.voltage = (bus.sink_voltage_bound + 0.6) * bus.series_multiplier;
// increase debounce counter to 1 before limit
for (int i = 0; i < CONFIG_CONTROL_FREQUENCY; i++) {
load_out.control();
}
TEST_ASSERT_EQUAL(0, load_out.error_flags);
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load_out.state);
load_out.control(); // once more
TEST_ASSERT_EQUAL(ERR_LOAD_OVERVOLTAGE, load_out.error_flags);
TEST_ASSERT_EQUAL(LOAD_STATE_OFF, load_out.state);
}
void control_on_to_off_overcurrent()
{
DcBus bus = {};
@@ -209,6 +243,29 @@ void control_off_overvoltage_to_on_at_lower_voltage()
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load_out.state);
}
void control_off_overvoltage_to_on_at_lower_voltage_dual_battery()
{
DcBus bus = {};
LoadOutput load_out(&bus, &load_drv_set, &load_drv_init);
load_init(&load_out, false, 2);
bus.voltage = (load_out.overvoltage + 0.1) * bus.series_multiplier;
load_out.error_flags = ERR_LOAD_OVERVOLTAGE;
load_out.control();
TEST_ASSERT_EQUAL(ERR_LOAD_OVERVOLTAGE, load_out.error_flags);
TEST_ASSERT_EQUAL(LOAD_STATE_OFF, load_out.state);
bus.voltage = (load_out.overvoltage - 0.1) * bus.series_multiplier; // test hysteresis
load_out.control();
TEST_ASSERT_EQUAL(ERR_LOAD_OVERVOLTAGE, load_out.error_flags);
TEST_ASSERT_EQUAL(LOAD_STATE_OFF, load_out.state);
bus.voltage = (load_out.overvoltage - load_out.ov_hysteresis - 0.1) * bus.series_multiplier;
load_out.control();
TEST_ASSERT_EQUAL(0, load_out.error_flags);
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load_out.state);
}
void control_off_short_circuit_flag_reset()
{
DcBus bus = {};
@@ -236,8 +293,10 @@ void load_tests()
// control tests
RUN_TEST(control_off_to_on_if_everything_fine);
RUN_TEST(control_off_to_on_if_everything_fine_dual_battery);
RUN_TEST(control_on_to_off_shedding);
RUN_TEST(control_on_to_off_overvoltage);
RUN_TEST(control_on_to_off_overvoltage_dual_battery);
RUN_TEST(control_on_to_off_overcurrent);
RUN_TEST(control_on_to_off_voltage_dip);
RUN_TEST(control_on_to_off_bus_limit);
@@ -246,6 +305,7 @@ void load_tests()
RUN_TEST(control_off_shedding_to_on_after_delay);
RUN_TEST(control_off_overcurrent_to_on_after_delay);
RUN_TEST(control_off_overvoltage_to_on_at_lower_voltage);
RUN_TEST(control_off_overvoltage_to_on_at_lower_voltage_dual_battery);
RUN_TEST(control_off_short_circuit_flag_reset);
// ToDo: What to do if port current is above the limit, but the hardware can still handle it?