ADC alerts and emergency stop functions added

Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
This commit is contained in:
Martin Jaeger
2019-11-04 18:12:00 +01:00
parent 7412b11002
commit 7874b8b4d6
11 changed files with 198 additions and 3 deletions
+6
View File
@@ -209,6 +209,12 @@ void PwmSwitch::control()
}
}
void PwmSwitch::emergency_stop()
{
pwm_signal_stop();
off_timestamp = time(NULL);
}
float PwmSwitch::get_duty_cycle()
{
return pwm_signal_get_duty_cycle();