ADC alerts and emergency stop functions added

Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
This commit is contained in:
Martin Jaeger
2019-11-04 18:12:00 +01:00
parent 7412b11002
commit 7874b8b4d6
11 changed files with 198 additions and 3 deletions
+2
View File
@@ -165,6 +165,8 @@ int main()
load.state_machine();
adc_set_alerts(); // update regularly to cover changed configurations
eeprom_update();
leds_update_1s();