Solar, bat and load power added to data objects

This commit is contained in:
Martin Jaeger
2019-06-18 17:04:33 +02:00
parent 375fcee514
commit 690e204a16
11 changed files with 36 additions and 29 deletions
+4 -1
View File
@@ -131,7 +131,7 @@ const data_object_t data_objects[] = {
{0x70, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(ls_bus.voltage), "Bat_V"},
{0x71, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(hs_bus.voltage), "Solar_V"},
{0x72, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(ls_bus.current), "Bat_A"},
{0x73, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(load.current), "Load_A"},
{0x73, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(load.bus->current), "Load_A"},
{0x74, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 1, (void*) &(charger.bat_temperature), "Bat_degC"},
{0x75, TS_OUTPUT, TS_READ_ALL, TS_T_BOOL, 1, (void*) &(charger.ext_temp_sensor), "BatTempExt"},
{0x76, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 1, (void*) &(mcu_temp), "MCU_degC"},
@@ -143,6 +143,9 @@ const data_object_t data_objects[] = {
{0x7A, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(hs_bus.current), "Solar_A"},
{0x7B, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(ls_bus.chg_voltage_target), "BatTarget_V"},
{0x7C, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(ls_bus.chg_current_max), "BatTarget_A"},
{0x7D, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(ls_bus.power), "Bat_W"},
{0x7E, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(hs_bus.power), "Solar_W"},
{0x7F, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(load_bus.power), "Load_W"},
// RECORDED DATA ///////////////////////////////////////////////////////
// using IDs >= 0xA0