Discharge and load output control improvements
- Charge/discharge control in charger class sets global error flags - Load state machine analyzes error flags to distinguish reasons for switching load off - Temperature errors now identified correctly (issue #59) - Delay before load re-connect after low voltage or overcurrent event now configurable - Unit tests added
This commit is contained in:
@@ -0,0 +1,252 @@
|
||||
|
||||
#include "tests.h"
|
||||
#include "adc_dma_stub.h"
|
||||
#include "adc_dma.h"
|
||||
|
||||
#include <time.h>
|
||||
#include <stdio.h>
|
||||
#include <math.h>
|
||||
|
||||
#include "main.h"
|
||||
|
||||
/*
|
||||
enum LoadState {
|
||||
LOAD_STATE_DISABLED = 0, ///< Actively disabled
|
||||
LOAD_STATE_ON, ///< Normal state: On
|
||||
LOAD_STATE_OFF_LOW_SOC, ///< Off to protect battery (overrules target setting)
|
||||
LOAD_STATE_OFF_OVERCURRENT, ///< Off to protect charge controller (overrules target setting)
|
||||
LOAD_STATE_OFF_OVERVOLTAGE, ///< Off to protect loads (overrules target setting)
|
||||
LOAD_STATE_OFF_SHORT_CIRCUIT ///< Off to protect charge controller (overrules target setting)
|
||||
};
|
||||
*/
|
||||
|
||||
void disabled_to_on_if_everything_fine()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
port.pos_current_limit = 10;
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state);
|
||||
}
|
||||
|
||||
void disabled_to_off_low_soc_if_error_flag_set()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
port.pos_current_limit = 0;
|
||||
log_data.error_flags = 1 << ERR_BAT_UNDERVOLTAGE;
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_LOW_SOC, load.state);
|
||||
}
|
||||
|
||||
void disabled_to_off_bat_temp_if_error_flag_set()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
port.pos_current_limit = 0;
|
||||
|
||||
// overtemp
|
||||
log_data.error_flags = 1 << ERR_BAT_CHG_OVERTEMP;
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_BAT_TEMP, load.state);
|
||||
|
||||
// undertemp
|
||||
load.state = LOAD_STATE_DISABLED;
|
||||
log_data.error_flags = 1 << ERR_BAT_CHG_UNDERTEMP;
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_BAT_TEMP, load.state);
|
||||
}
|
||||
|
||||
void off_low_soc_to_on_after_delay()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
load.state = LOAD_STATE_OFF_LOW_SOC;
|
||||
port.pos_current_limit = 10;
|
||||
|
||||
load.lvd_timestamp = time(NULL) - load.lvd_recovery_delay + 1;
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_LOW_SOC, load.state);
|
||||
|
||||
load.lvd_timestamp = time(NULL) - load.lvd_recovery_delay - 1;
|
||||
load.state_machine();
|
||||
load.state_machine(); // call twice as it goes through disabled state
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state);
|
||||
}
|
||||
|
||||
void off_overcurrent_to_on_after_delay()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
load.state = LOAD_STATE_OFF_OVERCURRENT;
|
||||
port.pos_current_limit = 10;
|
||||
|
||||
load.overcurrent_timestamp = time(NULL) - load.overcurrent_recovery_delay + 1;
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERCURRENT, load.state);
|
||||
|
||||
load.overcurrent_timestamp = time(NULL) - load.overcurrent_recovery_delay - 1;
|
||||
load.state_machine();
|
||||
load.state_machine(); // call twice as it goes through disabled state
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state);
|
||||
}
|
||||
|
||||
void off_overvoltage_to_on_at_lower_voltage()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
port.pos_current_limit = 10;
|
||||
load.state = LOAD_STATE_OFF_OVERVOLTAGE;
|
||||
port.voltage = port.sink_voltage_max + 0.1;
|
||||
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load.state);
|
||||
|
||||
port.voltage = port.sink_voltage_max - 0.1; // test hysteresis
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load.state);
|
||||
|
||||
port.voltage = port.sink_voltage_max - 0.6;
|
||||
load.state_machine();
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state);
|
||||
}
|
||||
|
||||
void off_short_circuit_to_disabled()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
port.pos_current_limit = 10;
|
||||
load.state = LOAD_STATE_OFF_SHORT_CIRCUIT;
|
||||
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_SHORT_CIRCUIT, load.state);
|
||||
|
||||
load.enable = false; // this is like a manual reset
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_DISABLED, load.state);
|
||||
}
|
||||
|
||||
void on_to_off_low_soc_if_error_flag_set()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
load.state = LOAD_STATE_ON;
|
||||
port.pos_current_limit = 0;
|
||||
log_data.error_flags = 1 << ERR_BAT_UNDERVOLTAGE;
|
||||
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_LOW_SOC, load.state);
|
||||
}
|
||||
|
||||
void on_to_off_bat_temp_if_error_flag_set()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
port.pos_current_limit = 0;
|
||||
|
||||
load.state = LOAD_STATE_ON;
|
||||
log_data.error_flags = 1 << ERR_BAT_DIS_OVERTEMP;
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_BAT_TEMP, load.state);
|
||||
|
||||
load.state = LOAD_STATE_ON;
|
||||
log_data.error_flags = 1 << ERR_BAT_DIS_UNDERTEMP;
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_BAT_TEMP, load.state);
|
||||
}
|
||||
|
||||
void on_to_disabled_if_enable_false()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
port.pos_current_limit = 10;
|
||||
|
||||
load.state = LOAD_STATE_ON;
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state);
|
||||
|
||||
load.enable = false;
|
||||
load.state_machine();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_DISABLED, load.state);
|
||||
}
|
||||
|
||||
void control_off_overvoltage()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
port.pos_current_limit = 10;
|
||||
port.voltage = 14.7;
|
||||
load.state = LOAD_STATE_ON;
|
||||
|
||||
// increase debounce counter to 1 before limit
|
||||
for (int i = 0; i < CONTROL_FREQUENCY; i++) {
|
||||
load.control();
|
||||
}
|
||||
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state);
|
||||
load.control(); // once more
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load.state);
|
||||
}
|
||||
|
||||
extern float mcu_temp;
|
||||
|
||||
void control_off_overcurrent()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
port.pos_current_limit = 10; // this is currently not considered, as it is lower than hardware limit
|
||||
port.current = LOAD_CURRENT_MAX * 2;
|
||||
load.state = LOAD_STATE_ON;
|
||||
mcu_temp = 25;
|
||||
load.junction_temperature = 25;
|
||||
|
||||
load.control();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state);
|
||||
|
||||
// 2x current = 4x heat generation: Should definitely trigger after waiting one time constant
|
||||
int trigger_steps = MOSFET_THERMAL_TIME_CONSTANT * CONTROL_FREQUENCY;
|
||||
for (int i = 0; i <= trigger_steps; i++) {
|
||||
load.control();
|
||||
}
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERCURRENT, load.state);
|
||||
}
|
||||
|
||||
void load_tests()
|
||||
{
|
||||
UNITY_BEGIN();
|
||||
|
||||
// state_machine tests
|
||||
RUN_TEST(disabled_to_on_if_everything_fine);
|
||||
RUN_TEST(disabled_to_off_low_soc_if_error_flag_set);
|
||||
RUN_TEST(disabled_to_off_bat_temp_if_error_flag_set);
|
||||
RUN_TEST(off_low_soc_to_on_after_delay);
|
||||
RUN_TEST(off_overcurrent_to_on_after_delay);
|
||||
RUN_TEST(off_overvoltage_to_on_at_lower_voltage);
|
||||
RUN_TEST(off_short_circuit_to_disabled);
|
||||
RUN_TEST(on_to_off_low_soc_if_error_flag_set);
|
||||
RUN_TEST(on_to_off_bat_temp_if_error_flag_set);
|
||||
RUN_TEST(on_to_disabled_if_enable_false);
|
||||
|
||||
// control tests
|
||||
RUN_TEST(control_off_overvoltage);
|
||||
RUN_TEST(control_off_overcurrent);
|
||||
|
||||
// ToDo: What to do if port current is above the limit, but the hardware can still handle it?
|
||||
|
||||
// ToDo: Additional USB output state machine tests
|
||||
|
||||
UNITY_END();
|
||||
}
|
||||
Reference in New Issue
Block a user