Discharge and load output control improvements
- Charge/discharge control in charger class sets global error flags - Load state machine analyzes error flags to distinguish reasons for switching load off - Temperature errors now identified correctly (issue #59) - Delay before load re-connect after low voltage or overcurrent event now configurable - Unit tests added
This commit is contained in:
@@ -97,6 +97,8 @@ const data_object_t data_objects[] = {
|
||||
{0x43, TS_CONF, TS_READ_ALL | TS_WRITE_ALL, TS_T_FLOAT32, 2, (void*) &(bat_conf_user.voltage_load_reconnect), "LoadReconnect_V"},
|
||||
//{0x44, TS_CONF, TS_READ_ALL | TS_WRITE_ALL, TS_T_FLOAT32, 2, (void*) &(bat_conf_user.voltage_load_disconnect), "UsbDisconnect_V"},
|
||||
//{0x45, TS_CONF, TS_READ_ALL | TS_WRITE_ALL, TS_T_FLOAT32, 2, (void*) &(bat_conf_user.voltage_load_reconnect), "UsbReconnect_V"},
|
||||
{0x46, TS_CONF, TS_READ_ALL | TS_WRITE_ALL, TS_T_FLOAT32, 2, (void*) &(load.overcurrent_recovery_delay), "LoadOCRecovery_s"},
|
||||
{0x47, TS_CONF, TS_READ_ALL | TS_WRITE_ALL, TS_T_FLOAT32, 2, (void*) &(load.lvd_recovery_delay), "LoadUVRecovery_s"},
|
||||
|
||||
// other configuration items
|
||||
//{0x33, TS_CONF, TS_READ_ALL | TS_WRITE_ALL, TS_T_BOOL, 2, (void*) &(??), "WarningIndicator"}, // can be set externally
|
||||
@@ -118,7 +120,7 @@ const data_object_t data_objects[] = {
|
||||
// using IDs >= 0x70 except for high priority data objects
|
||||
|
||||
// high priority data objects (low IDs)
|
||||
{0x04, TS_OUTPUT, TS_READ_ALL, TS_T_UINT16, 0, (void*) &(load.switch_state), "LoadState"},
|
||||
{0x04, TS_OUTPUT, TS_READ_ALL, TS_T_UINT16, 0, (void*) &(load.state), "LoadState"},
|
||||
{0x05, TS_OUTPUT, TS_READ_ALL, TS_T_UINT16, 0, (void*) &(load.usb_state), "UsbState"},
|
||||
{0x06, TS_OUTPUT, TS_READ_ALL, TS_T_UINT16, 0, (void*) &(charger.soc), "SOC_%"}, // output will be uint8_t
|
||||
|
||||
|
||||
Reference in New Issue