Add DC/DC HV side output enable switch

This commit is contained in:
Martin Jäger
2020-07-23 12:55:38 +02:00
parent 7dfcac4037
commit 6316dcd57f
4 changed files with 47 additions and 0 deletions
@@ -38,6 +38,7 @@
leds {
compatible = "gpio-leds";
pwr {
gpios = <&gpioc 15 GPIO_ACTIVE_HIGH>;
label = "Power LED";
@@ -46,21 +47,29 @@
outputs {
compatible = "outputs";
pwm_switch {
label = "PWM power switch (solar panel)";
pwms = <&pwm3 2 (20*1000*1000)>; /* 20 ms period = 50 Hz */
current-max = <20>;
kconfig-flag; /* make node visible in Kconfig */
};
load {
label = "Load output";
gpios = <&gpiob 15 GPIO_ACTIVE_LOW>;
current-max = <20>;
};
charge_pump {
label = "Charge pump for HS MOSFET drivers";
pwms = <&pwm8 1 200000>; /* 200 us period = 5 kHz */
};
hv-ext-sense {
label = "HV external sense and switch";
gpios = <&gpiob 12 GPIO_ACTIVE_LOW>;
};
};
adc-inputs {
+5
View File
@@ -51,6 +51,11 @@
label = "CAN disable / standby";
gpios = <&gpiob 14 GPIO_ACTIVE_LOW>;
};
hv-ext-sense {
label = "HV external sense and switch";
gpios = <&gpiob 12 GPIO_ACTIVE_LOW>;
};
};
adc-inputs {
+22
View File
@@ -8,6 +8,10 @@
#include <zephyr.h>
#ifndef UNIT_TEST
#include <drivers/gpio.h>
#endif
#include <math.h> // for fabs function
#include <stdlib.h> // for min/max function
#include <stdio.h>
@@ -290,4 +294,22 @@ void Dcdc::fuse_destruction()
counter++;
}
void Dcdc::output_hvs_enable()
{
#ifdef DT_OUTPUTS_HV_EXT_SENSE_GPIOS_CONTROLLER
struct device *dev_hv_ext = device_get_binding(DT_OUTPUTS_HV_EXT_SENSE_GPIOS_CONTROLLER);
gpio_pin_configure(dev_hv_ext, DT_OUTPUTS_HV_EXT_SENSE_GPIOS_PIN,
DT_OUTPUTS_HV_EXT_SENSE_GPIOS_FLAGS | GPIO_OUTPUT_ACTIVE);
#endif
}
void Dcdc::output_hvs_disable()
{
#ifdef DT_OUTPUTS_HV_EXT_SENSE_GPIOS_CONTROLLER
struct device *dev_hv_ext = device_get_binding(DT_OUTPUTS_HV_EXT_SENSE_GPIOS_CONTROLLER);
gpio_pin_configure(dev_hv_ext, DT_OUTPUTS_HV_EXT_SENSE_GPIOS_PIN,
DT_OUTPUTS_HV_EXT_SENSE_GPIOS_FLAGS | GPIO_OUTPUT_INACTIVE);
#endif
}
#endif /* DT_COMPAT_DCDC */
+11
View File
@@ -130,6 +130,17 @@ private:
* @returns 0 if everything is fine, error number otherwise
*/
int perturb_observe_controller();
/**
* If manual control of the reverse polarity MOSFET on the high-side is available, this
* function enables it to use the high voltage side as output.
*/
void output_hvs_enable();
/**
* Disable the reverse polarity MOSFET on the high-sied (if option available)
*/
void output_hvs_disable();
};
#endif // __cplusplus