Load protection improvements
- Switched back to older mbed version, as update broke comparator function - Added voltage dip detection to disconnect load if charge controller is connected to small battery or with bad wires and short circuit detection doesn't trigger - Added more error flags to diagnose reasons for load disconnect
This commit is contained in:
+31
-13
@@ -9,17 +9,6 @@
|
||||
|
||||
#include "main.h"
|
||||
|
||||
/*
|
||||
enum LoadState {
|
||||
LOAD_STATE_DISABLED = 0, ///< Actively disabled
|
||||
LOAD_STATE_ON, ///< Normal state: On
|
||||
LOAD_STATE_OFF_LOW_SOC, ///< Off to protect battery (overrules target setting)
|
||||
LOAD_STATE_OFF_OVERCURRENT, ///< Off to protect charge controller (overrules target setting)
|
||||
LOAD_STATE_OFF_OVERVOLTAGE, ///< Off to protect loads (overrules target setting)
|
||||
LOAD_STATE_OFF_SHORT_CIRCUIT ///< Off to protect charge controller (overrules target setting)
|
||||
};
|
||||
*/
|
||||
|
||||
void disabled_to_on_if_everything_fine()
|
||||
{
|
||||
PowerPort port;
|
||||
@@ -189,6 +178,8 @@ void control_off_overvoltage()
|
||||
port.pos_current_limit = 10;
|
||||
port.voltage = 14.7;
|
||||
load.state = LOAD_STATE_ON;
|
||||
load.voltage_prev = port.voltage;
|
||||
log_data.error_flags = 0;
|
||||
|
||||
// increase debounce counter to 1 before limit
|
||||
for (int i = 0; i < CONTROL_FREQUENCY; i++) {
|
||||
@@ -198,6 +189,7 @@ void control_off_overvoltage()
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state);
|
||||
load.control(); // once more
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load.state);
|
||||
TEST_ASSERT_EQUAL(1 << ERR_LOAD_OVERVOLTAGE, log_data.error_flags);
|
||||
}
|
||||
|
||||
extern float mcu_temp;
|
||||
@@ -208,20 +200,45 @@ void control_off_overcurrent()
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
port.pos_current_limit = 10; // this is currently not considered, as it is lower than hardware limit
|
||||
port.current = LOAD_CURRENT_MAX * 2;
|
||||
port.current = LOAD_CURRENT_MAX * 1.9; // with factor 2 it is switched off immediately
|
||||
port.voltage = 14;
|
||||
load.state = LOAD_STATE_ON;
|
||||
load.voltage_prev = port.voltage;
|
||||
mcu_temp = 25;
|
||||
load.junction_temperature = 25;
|
||||
log_data.error_flags = 0;
|
||||
|
||||
load.control();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state);
|
||||
|
||||
// 2x current = 4x heat generation: Should definitely trigger after waiting one time constant
|
||||
// almost 2x current = 4x heat generation: Should definitely trigger after waiting one time constant
|
||||
int trigger_steps = MOSFET_THERMAL_TIME_CONSTANT * CONTROL_FREQUENCY;
|
||||
for (int i = 0; i <= trigger_steps; i++) {
|
||||
load.control();
|
||||
}
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERCURRENT, load.state);
|
||||
TEST_ASSERT_EQUAL(1 << ERR_LOAD_OVERCURRENT, log_data.error_flags);
|
||||
}
|
||||
|
||||
void control_off_voltage_dip()
|
||||
{
|
||||
PowerPort port;
|
||||
LoadOutput load(&port);
|
||||
port.init_load(14.6);
|
||||
load.voltage_prev = port.voltage;
|
||||
load.state = LOAD_STATE_ON;
|
||||
mcu_temp = 25;
|
||||
load.junction_temperature = 25;
|
||||
log_data.error_flags = 0;
|
||||
|
||||
port.voltage = 14;
|
||||
load.control();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state);
|
||||
|
||||
port.voltage = 14 * 0.74;
|
||||
load.control();
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERCURRENT, load.state);
|
||||
TEST_ASSERT_EQUAL(1 << ERR_LOAD_VOLTAGE_DIP, log_data.error_flags);
|
||||
}
|
||||
|
||||
void load_tests()
|
||||
@@ -243,6 +260,7 @@ void load_tests()
|
||||
// control tests
|
||||
RUN_TEST(control_off_overvoltage);
|
||||
RUN_TEST(control_off_overcurrent);
|
||||
RUN_TEST(control_off_voltage_dip);
|
||||
|
||||
// ToDo: What to do if port current is above the limit, but the hardware can still handle it?
|
||||
|
||||
|
||||
Reference in New Issue
Block a user