Load protection improvements

- Switched back to older mbed version, as update broke comparator function
- Added voltage dip detection to disconnect load if charge controller is connected to small
  battery or with bad wires and short circuit detection doesn't trigger
- Added more error flags to diagnose reasons for load disconnect
This commit is contained in:
Martin Jaeger
2019-10-30 17:31:16 +01:00
parent 975c03affd
commit 5b4df98656
6 changed files with 97 additions and 31 deletions
+52 -16
View File
@@ -20,6 +20,7 @@
#include "hardware.h"
#include "leds.h"
#include "log.h"
#include "debug.h"
volatile bool short_circuit = false;
@@ -97,7 +98,7 @@ static void short_circuit_comp_init()
COMP2->CSR |= COMP_INPUT_PLUS_IO2;
// select VREFINT divider as negative input
COMP2->CSR |= COMP_INPUT_MINUS_VREFINT;
COMP2->CSR |= COMP_INPUT_MINUS_1_4VREFINT;
// propagate comparator value to LPTIM input
COMP2->CSR |= COMP_CSR_COMP2LPTIM1IN1;
@@ -149,19 +150,29 @@ void LoadOutput::switch_set(bool enabled)
#ifdef PIN_LOAD_EN
DigitalOut load_enable(PIN_LOAD_EN);
if (enabled) load_enable = 1;
else load_enable = 0;
if (enabled) {
load_enable = 1;
}
else {
load_enable = 0;
}
#endif
#ifdef PIN_LOAD_DIS
DigitalOut load_disable(PIN_LOAD_DIS);
#ifdef PIN_I_LOAD_COMP
if (enabled) lptim_init();
#else
if (enabled) load_disable = 0;
#endif
else load_disable = 1;
printf("Load enabled = %d\n", enabled);
#ifdef PIN_I_LOAD_COMP
if (enabled) {
lptim_init();
}
#else
if (enabled) {
load_disable = 0;
}
#endif
else {
load_disable = 1;
}
print_info("Load enabled = %d\n", enabled);
#endif
}
@@ -251,7 +262,6 @@ void LoadOutput::usb_state_machine()
void LoadOutput::state_machine()
{
//printf("Load State: %d\n", state);
switch (state) {
case LOAD_STATE_DISABLED:
if (enable == true) {
@@ -289,14 +299,16 @@ void LoadOutput::state_machine()
}
break;
case LOAD_STATE_OFF_LOW_SOC:
// wait at least one hour
// wait configured time
if (time(NULL) - lvd_timestamp > lvd_recovery_delay) {
state = LOAD_STATE_DISABLED; // switch to normal mode again
}
break;
case LOAD_STATE_OFF_OVERCURRENT:
// wait some time
// wait configured time
if (time(NULL) - overcurrent_timestamp > overcurrent_recovery_delay) {
log_data.error_flags &= ~(1 << ERR_LOAD_OVERCURRENT);
log_data.error_flags &= ~(1 << ERR_LOAD_VOLTAGE_DIP);
state = LOAD_STATE_DISABLED; // switch to normal mode again
}
break;
@@ -304,6 +316,7 @@ void LoadOutput::state_machine()
if (port->voltage < (port->sink_voltage_max - 0.5) &&
port->voltage < (LOW_SIDE_VOLTAGE_MAX - 0.5))
{
log_data.error_flags &= ~(1 << ERR_LOAD_OVERVOLTAGE);
state = LOAD_STATE_DISABLED; // switch to normal mode again
}
break;
@@ -311,6 +324,7 @@ void LoadOutput::state_machine()
// stay here until the charge controller is reset or load is switched off remotely
if (enable == false) {
short_circuit = false;
log_data.error_flags &= ~(1 << ERR_LOAD_SHORT_CIRCUIT);
state = LOAD_STATE_DISABLED; // switch to normal mode again
}
break;
@@ -323,7 +337,11 @@ void LoadOutput::state_machine()
void LoadOutput::control()
{
if (short_circuit) {
state = LOAD_STATE_OFF_SHORT_CIRCUIT;
if (state != LOAD_STATE_OFF_SHORT_CIRCUIT) {
state = LOAD_STATE_OFF_SHORT_CIRCUIT;
log_data.error_flags |= (1 << ERR_LOAD_SHORT_CIRCUIT);
print_error("Load short circuit detected\n");
}
return;
}
@@ -334,13 +352,30 @@ void LoadOutput::control()
(LOAD_CURRENT_MAX * LOAD_CURRENT_MAX) * (MOSFET_MAX_JUNCTION_TEMP - 25)
) / (MOSFET_THERMAL_TIME_CONSTANT * CONTROL_FREQUENCY);
if (junction_temperature > MOSFET_MAX_JUNCTION_TEMP) {
if (junction_temperature > MOSFET_MAX_JUNCTION_TEMP
|| port->current > LOAD_CURRENT_MAX * 2)
{
switch_set(false);
usb_set(false);
leds_flicker(LED_LOAD);
state = LOAD_STATE_OFF_OVERCURRENT;
log_data.error_flags |= (1 << ERR_LOAD_OVERCURRENT);
print_error("Load overcurrent detected\n");
overcurrent_timestamp = time(NULL);
}
// overcurrent detected because of voltage dip by 25%
if (port->voltage < voltage_prev * 0.75 && voltage_prev != 0) {
switch_set(false);
usb_set(false);
leds_flicker(LED_LOAD);
state = LOAD_STATE_OFF_OVERCURRENT;
log_data.error_flags |= (1 << ERR_LOAD_VOLTAGE_DIP);
print_error("Load voltage dip detected\n");
overcurrent_timestamp = time(NULL);
}
voltage_prev = port->voltage;
static int debounce_counter = 0;
if (port->voltage > port->sink_voltage_max ||
port->voltage > LOW_SIDE_VOLTAGE_MAX)
@@ -349,9 +384,10 @@ void LoadOutput::control()
if (debounce_counter > CONTROL_FREQUENCY) { // waited 1s before setting the flag
switch_set(false);
usb_set(false);
print_error("Load overvoltage detected\n");
state = LOAD_STATE_OFF_OVERVOLTAGE;
overcurrent_timestamp = time(NULL);
log_data.error_flags |= (1 << ERR_BAT_OVERVOLTAGE);
log_data.error_flags |= (1 << ERR_LOAD_OVERVOLTAGE);
}
}
else {