Passing of bat voltage and current limits to other ports updated

This commit is contained in:
Martin Jaeger
2019-10-23 07:29:05 +02:00
parent f879dc9c5d
commit 515b098e85
6 changed files with 67 additions and 17 deletions
+6 -1
View File
@@ -148,7 +148,10 @@ int main()
charger.charge_control(&bat_conf);
#if FEATURE_DCDC_CONVERTER
update_dcdc_current_targets(&dcdc_lv_port, &bat_terminal, &load_terminal);
bat_terminal.pass_voltage_targets(&dcdc_lv_port);
#endif
#if FEATURE_PWM_SWITCH
bat_terminal.pass_voltage_targets(&pwm_port_int);
#endif
load.state_machine();
@@ -180,11 +183,13 @@ void system_control()
update_measurements();
#if FEATURE_PWM_SWITCH
ports_update_current_limits(&pwm_port_int, &bat_terminal, &load_terminal);
pwm_switch.control();
leds_set_charging(pwm_switch.active());
#endif
#if FEATURE_DCDC_CONVERTER
ports_update_current_limits(&dcdc_lv_port, &bat_terminal, &load_terminal);
dcdc.control(); // control of DC/DC including MPPT algorithm
leds_set_charging(half_bridge_enabled());
#endif