Restructuring of data types (structs) and files

- dcdc_port_t renamed to power_port_t for future use in PWM charge controllers
- structs.h split into battery.h, log.h and charger.h
- bat_charger.cpp/h split into battery.cpp/h and charger.cpp/h
This commit is contained in:
Martin Jaeger
2019-03-10 17:19:44 +01:00
parent 871c8e46be
commit 4e0b7f2a12
19 changed files with 428 additions and 324 deletions
+251
View File
@@ -0,0 +1,251 @@
/* LibreSolar MPPT charge controller firmware
* Copyright (c) 2016-2018 Martin Jäger (www.libre.solar)
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
#include "mbed.h"
#include "battery.h"
#include "config.h"
#include "pcb.h"
#include "power_port.h"
#include "load.h"
#include "log.h"
#include <math.h> // for fabs function
// ToDo: Remove global definitions!
extern power_port_t ls_port;
extern power_port_t hs_port;
extern load_output_t load;
extern log_data_t log_data;
void battery_init(battery_t *bat, battery_user_settings_t *bat_user)
{
// core battery pack specification (set in config.h)
bat->type = BATTERY_TYPE;
bat->num_cells = BATTERY_NUM_CELLS;
bat->nominal_capacity = BATTERY_CAPACITY;
bat->num_batteries = 1; // initialize with only one battery in series
bat->soh = 100; // assume new battery
// common values for all batteries
bat->charge_current_max = bat->nominal_capacity; // 1C should be safe for all batteries
bat->time_limit_recharge = 60; // sec
bat->time_limit_CV = 120*60; // sec
switch (bat->type)
{
case BAT_TYPE_FLOODED:
case BAT_TYPE_AGM:
case BAT_TYPE_GEL:
bat->cell_voltage_max = 2.4;
bat->cell_voltage_recharge = 2.3;
bat->cell_voltage_load_disconnect = 1.95;
bat->cell_voltage_load_reconnect = 2.1;
bat->cell_voltage_absolute_min = 1.8;
bat->cell_ocv_full = 2.2;
bat->cell_ocv_empty = 1.9;
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
bat->current_cutoff_CV = bat->nominal_capacity * 0.04; // 3-5 % of C/1
bat->trickle_enabled = true;
bat->time_trickle_recharge = 30*60;
// http://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
bat->cell_voltage_trickle = (bat->type == BAT_TYPE_FLOODED) ? 2.25 : 2.3;
bat->equalization_enabled = false;
bat->cell_voltage_equalization = 2.5;
bat->time_limit_equalization = 60*60;
bat->current_limit_equalization = (1.0 /7.0) * bat->nominal_capacity;
bat->equalization_trigger_time = 8; // weeks
bat->equalization_trigger_deep_cycles = 10; // times
// not yet implemented...
bat->temperature_compensation = -0.003; // -3 mV/°C/cell
break;
case BAT_TYPE_LFP:
bat->cell_voltage_max = 3.55; // CV voltage
bat->cell_voltage_recharge = 3.35;
bat->cell_voltage_load_disconnect = 3.0;
bat->cell_voltage_load_reconnect = 3.15;
bat->cell_voltage_absolute_min = 2.0;
bat->cell_ocv_full = 3.4; // will give really bad SOC calculation
bat->cell_ocv_empty = 3.0; // because of flat OCV of LFP cells...
bat->current_cutoff_CV = bat->nominal_capacity / 10; // C/10 cut-off at end of CV phase by default
bat->trickle_enabled = false;
bat->equalization_enabled = false;
bat->temperature_compensation = 0.0;
break;
case BAT_TYPE_NMC:
case BAT_TYPE_NMC_HV:
bat->cell_voltage_max = (bat->type == BAT_TYPE_NMC_HV) ? 4.35 : 4.20;
bat->cell_voltage_recharge = 3.9;
bat->cell_voltage_load_disconnect = 3.3;
bat->cell_voltage_load_reconnect = 3.6;
bat->cell_voltage_absolute_min = 2.5;
bat->cell_ocv_full = 4.0;
bat->cell_ocv_empty = 3.0;
bat->current_cutoff_CV = bat->nominal_capacity / 10; // C/10 cut-off at end of CV phase by default
bat->trickle_enabled = false;
bat->equalization_enabled = false;
bat->temperature_compensation = 0.0;
break;
case BAT_TYPE_NONE:
case BAT_TYPE_CUSTOM:
break;
}
// initialize bat_user
bat_user->nominal_capacity = bat->nominal_capacity;
bat_user->voltage_max = bat->num_cells * bat->cell_voltage_max;
bat_user->voltage_recharge = bat->num_cells * bat->cell_voltage_recharge;
bat_user->voltage_load_reconnect = bat->num_cells * bat->cell_voltage_load_reconnect;
bat_user->voltage_load_disconnect = bat->num_cells * bat->cell_voltage_load_disconnect;
bat_user->voltage_absolute_min = bat->num_cells * bat->cell_voltage_absolute_min;
bat_user->charge_current_max = bat->charge_current_max;
bat_user->current_cutoff_CV = bat->current_cutoff_CV;
bat_user->time_limit_CV = bat->time_limit_CV;
bat_user->trickle_enabled = bat->trickle_enabled;
bat_user->time_trickle_recharge = bat->time_trickle_recharge;
bat_user->temperature_compensation = bat->temperature_compensation;
// call user function (defined in config.cpp to overwrite above initializations)
battery_init_user(bat, bat_user);
}
// weak function to be overridden by user in config.cpp
WEAK void battery_init_user(battery_t *bat, battery_user_settings_t *bat_user) {;}
// checks settings in bat_user for plausibility and writes them to bat if everything is fine
bool battery_user_settings(battery_t *bat, battery_user_settings_t *bat_user)
{
// things to check:
// - cell_voltage_XXX in the range of what the charger can handle?
// - load_disconnect/reconnect hysteresis makes sense?
// - cutoff current not extremely low/high
// - capacity plausible
if (bat_user->voltage_max > LOW_SIDE_VOLTAGE_MAX &&
bat_user->voltage_load_reconnect > (bat_user->voltage_load_disconnect + 0.8) &&
bat_user->voltage_recharge < (bat_user->voltage_max - 0.6) &&
bat_user->voltage_recharge > (bat_user->voltage_load_disconnect + 1) &&
bat_user->voltage_load_disconnect > (bat_user->voltage_absolute_min + 0.5) &&
bat_user->current_cutoff_CV < (bat_user->nominal_capacity / 9.0) && // C/10 or lower allowed
bat_user->current_cutoff_CV > 0.01 &&
(bat_user->trickle_enabled == false ||
(bat_user->voltage_trickle < bat_user->voltage_max &&
bat_user->voltage_trickle > bat_user->voltage_load_disconnect))
) {
// TODO: stop DC/DC
bat->type = BAT_TYPE_CUSTOM;
bat->num_cells = 1; // custom battery defines voltages on battery level
bat->nominal_capacity = bat_user->nominal_capacity;
bat->cell_voltage_max = bat_user->voltage_max;
bat->cell_voltage_recharge = bat_user->voltage_recharge;
bat->cell_voltage_load_reconnect = bat_user->voltage_load_reconnect;
bat->cell_voltage_load_disconnect = bat_user->voltage_load_disconnect;
bat->cell_voltage_absolute_min = bat_user->voltage_absolute_min;
bat->charge_current_max = bat_user->charge_current_max;
bat->current_cutoff_CV = bat_user->current_cutoff_CV;
bat->time_limit_CV = bat_user->time_limit_CV;
bat->trickle_enabled = bat_user->trickle_enabled;
bat->time_trickle_recharge = bat_user->time_trickle_recharge;
bat->temperature_compensation = bat_user->temperature_compensation;
// TODO:
// - update also DC/DC etc. (now this function only works at system startup)
// - restart DC/DC
return true;
}
return false;
}
//----------------------------------------------------------------------------
// must be called exactly once per second, otherwise energy calculation gets wrong
void battery_update_energy(battery_t *bat, float voltage, float current)
{
// static variables so that the are not reset during each function call
static int seconds_zero_solar = 0;
static int soc_filtered = 0; // SOC / 100 for better filtering
// stores the input/output energy status of previous day and to add
// xxx_Wh_day only once per day and increase accuracy
static uint32_t input_Wh_total_prev = bat->input_Wh_total;
static uint32_t output_Wh_total_prev = bat->output_Wh_total;
if (hs_port.voltage < ls_port.voltage) {
seconds_zero_solar += 1;
}
else {
// solar voltage > battery voltage after 5 hours of night time means sunrise in the morning
// --> reset daily energy counters
if (seconds_zero_solar > 60*60*5) {
//printf("Night!\n");
log_data.day_counter++;
input_Wh_total_prev = bat->input_Wh_total;
output_Wh_total_prev = bat->output_Wh_total;
bat->input_Wh_day = 0.0;
bat->output_Wh_day = 0.0;
}
seconds_zero_solar = 0;
}
bat->input_Wh_day += voltage * current / 3600.0; // timespan = 1s, so no multiplication with time
bat->output_Wh_day += load.current * ls_port.voltage / 3600.0;
bat->input_Wh_total = input_Wh_total_prev + (bat->input_Wh_day > 0 ? bat->input_Wh_day : 0);
bat->output_Wh_total = output_Wh_total_prev + (bat->output_Wh_day > 0 ? bat->output_Wh_day : 0);
bat->discharged_Ah += (load.current - current) / 3600.0;
if (fabs(current) < 0.2) {
int soc_new = (int)((voltage / bat->num_cells - bat->cell_ocv_empty) /
(bat->cell_ocv_full - bat->cell_ocv_empty) * 10000.0);
if (soc_new > 10000) {
soc_new = 10000;
}
else if (soc_new < 0) {
soc_new = 0;
}
if (soc_new > 500 && soc_filtered == 0) {
// bypass filter during initialization
soc_filtered = soc_new;
}
else {
// filtering to adjust SOC very slowly
soc_filtered += (soc_new - soc_filtered) / 100;
}
bat->soc = soc_filtered / 100;
}
}