DMA for ADC implemented, mbed Ticker removed, files restructured
- DMA partly uses ST HAL API (to be improved in further versions) - When using mbed ticker to trigger ADC, the program might stall --> use own timer instead - C++ libraries changed to more simple C-style functions and files (better compatibility with plain C environments)
This commit is contained in:
+189
@@ -0,0 +1,189 @@
|
||||
/* mbed library for a battery charge controller
|
||||
* Copyright (c) 2017 Martin Jäger (www.libre.solar)
|
||||
*
|
||||
* Licensed under the Apache License, Version 2.0 (the "License");
|
||||
* you may not use this file except in compliance with the License.
|
||||
* You may obtain a copy of the License at
|
||||
*
|
||||
* http://www.apache.org/licenses/LICENSE-2.0
|
||||
*
|
||||
* Unless required by applicable law or agreed to in writing, software
|
||||
* distributed under the License is distributed on an "AS IS" BASIS,
|
||||
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
||||
* See the License for the specific language governing permissions and
|
||||
* limitations under the License.
|
||||
*/
|
||||
|
||||
#include "charger.h"
|
||||
|
||||
|
||||
static ChargingProfile *_profile; // all charging profile variables
|
||||
static int _state; // valid states: enum charger_states
|
||||
static int _time_state_changed; // timestamp of last state change
|
||||
static float _target_voltage; // target voltage for current state
|
||||
static float _target_current; // target current for current state
|
||||
static int _time_voltage_limit_reached; // last time the CV limit was reached
|
||||
static bool _charging_enabled;
|
||||
static bool _discharging_enabled;
|
||||
|
||||
|
||||
// private function
|
||||
|
||||
/** Enter a different charger state
|
||||
*
|
||||
* @param next_state Next state (e.g. CHG_CC)
|
||||
*/
|
||||
void charger_enter_state(int next_state);
|
||||
|
||||
|
||||
void charger_init(ChargingProfile *profile)
|
||||
{
|
||||
_profile = profile;
|
||||
_charging_enabled = false;
|
||||
_time_state_changed = -profile->time_limit_recharge; // start immediately
|
||||
}
|
||||
|
||||
/*****************************************************************************
|
||||
* Charger state machine
|
||||
|
||||
## Idle
|
||||
Initial state of the charge controller. If the solar voltage is high enough
|
||||
and the battery is not full, charging in CC mode is started.
|
||||
|
||||
### CC / bulk charging
|
||||
The battery is charged with maximum possible current (MPPT algorithm is
|
||||
active) until the CV voltage limit is reached.
|
||||
|
||||
### CV / absorption charging
|
||||
Lead-acid batteries are charged for some time using a slightly higher charge
|
||||
voltage. After a current cutoff limit or a time limit is reached, the charger
|
||||
goes into trickle or equalization mode for lead-acid batteries or back into
|
||||
Standby for Li-ion batteries.
|
||||
|
||||
### Trickle charging
|
||||
This mode is kept forever for a lead-acid battery and keeps the battery at
|
||||
full state of charge. If too much power is drawn from the battery, the
|
||||
charger switches back into CC / bulk charging mode.
|
||||
|
||||
### Equalization charging
|
||||
This mode is only used for lead-acid batteries after several deep-discharge
|
||||
cycles or a very long period of time with no equalization. Voltage is
|
||||
increased to 15V or above, so care must be taken for the other system
|
||||
components attached to the battery. (currently, no equalization charging is
|
||||
enabled in the software)
|
||||
|
||||
*/
|
||||
|
||||
void charger_update(float battery_voltage, float battery_current) {
|
||||
|
||||
//printf("_time_state_change = %d, time = %d, v_bat = %f, i_bat = %f\n", _time_state_changed, time(NULL), battery_voltage, battery_current);
|
||||
|
||||
// Load management
|
||||
if (battery_voltage < _profile->cell_voltage_load_disconnect * _profile->num_cells) {
|
||||
_discharging_enabled = false;
|
||||
}
|
||||
if (battery_voltage >= _profile->cell_voltage_load_reconnect * _profile->num_cells) {
|
||||
_discharging_enabled = true;
|
||||
}
|
||||
|
||||
// state machine
|
||||
switch (_state) {
|
||||
|
||||
case CHG_IDLE: {
|
||||
if (battery_voltage < _profile->num_cells * _profile->cell_voltage_recharge
|
||||
&& (time(NULL) - _time_state_changed) > _profile->time_limit_recharge)
|
||||
{
|
||||
_target_current = _profile->charge_current_max;
|
||||
_target_voltage = _profile->num_cells * _profile->cell_voltage_max;
|
||||
_charging_enabled = true;
|
||||
charger_enter_state(CHG_CC);
|
||||
}
|
||||
break;
|
||||
}
|
||||
|
||||
case CHG_CC: {
|
||||
if (battery_voltage > _target_voltage) {
|
||||
_target_voltage = _profile->num_cells * _profile->cell_voltage_max;
|
||||
charger_enter_state(CHG_CV);
|
||||
}
|
||||
break;
|
||||
}
|
||||
|
||||
case CHG_CV: {
|
||||
if (battery_voltage >= _target_voltage) {
|
||||
_time_voltage_limit_reached = time(NULL);
|
||||
}
|
||||
|
||||
// cut-off limit reached because battery full (i.e. CV mode still
|
||||
// reached by available solar power within last 2s) or CV period long enough?
|
||||
if ((battery_current < _profile->current_cutoff_CV && (time(NULL) - _time_voltage_limit_reached) < 2)
|
||||
|| (time(NULL) - _time_state_changed) > _profile->time_limit_CV)
|
||||
{
|
||||
if (_profile->equalization_enabled) {
|
||||
// TODO: additional conditions!
|
||||
_target_voltage = _profile->num_cells * _profile->cell_voltage_equalization;
|
||||
_target_current = _profile->current_limit_equalization;
|
||||
charger_enter_state(CHG_EQUALIZATION);
|
||||
}
|
||||
else if (_profile->trickle_enabled) {
|
||||
_target_voltage = _profile->num_cells * _profile->cell_voltage_trickle;
|
||||
charger_enter_state(CHG_TRICKLE);
|
||||
}
|
||||
else {
|
||||
_target_current = 0;
|
||||
_charging_enabled = false;
|
||||
charger_enter_state(CHG_IDLE);
|
||||
}
|
||||
}
|
||||
break;
|
||||
}
|
||||
|
||||
case CHG_TRICKLE: {
|
||||
if (battery_voltage >= _target_voltage) {
|
||||
_time_voltage_limit_reached = time(NULL);
|
||||
}
|
||||
|
||||
if (time(NULL) - _time_voltage_limit_reached > _profile->time_trickle_recharge)
|
||||
{
|
||||
_target_current = _profile->charge_current_max;
|
||||
_target_voltage = _profile->num_cells * _profile->cell_voltage_max;
|
||||
charger_enter_state(CHG_CC);
|
||||
}
|
||||
// assumtion: trickle does not harm the battery --> never go back to idle
|
||||
// (for Li-ion battery: disable trickle!)
|
||||
break;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
void charger_enter_state(int next_state)
|
||||
{
|
||||
printf("Enter State: %d\n", next_state);
|
||||
_time_state_changed = time(NULL);
|
||||
_state = next_state;
|
||||
}
|
||||
|
||||
bool charger_discharging_enabled()
|
||||
{
|
||||
return _discharging_enabled;
|
||||
}
|
||||
|
||||
bool charger_charging_enabled()
|
||||
{
|
||||
return _charging_enabled;
|
||||
}
|
||||
|
||||
int charger_get_state()
|
||||
{
|
||||
return _state;
|
||||
}
|
||||
|
||||
float charger_read_target_current()
|
||||
{
|
||||
return _target_current;
|
||||
}
|
||||
|
||||
float charger_read_target_voltage()
|
||||
{
|
||||
return _target_voltage;
|
||||
}
|
||||