Move voltage control parameters to DcBus class

The sink and source voltage boundaries for droop control and battery
charge voltage management are now part of the DcBus class.
Also added source and sink current margins, which will be used by the
DC/DC for control targets instead of port current limits, which were
difficult to synchronize before.
This commit is contained in:
Martin Jaeger
2020-02-07 12:03:25 +01:00
parent a7d6dbc3b5
commit 43f90eea7c
16 changed files with 421 additions and 390 deletions
+23 -9
View File
@@ -30,6 +30,18 @@ uint32_t device_id = CONFIG_DEVICE_ID;
extern uint32_t timestamp;
#if CONFIG_LV_TERMINAL_BATTERY
#define bat_bus lv_bus
#elif CONFIG_HV_TERMINAL_BATTERY
#define bat_bus hv_bus
#endif
#if CONFIG_HV_TERMINAL_SOLAR
#define solar_bus hv_bus
#elif CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
#define solar_bus lv_bus
#endif
/** Data Objects
*
* IDs from 0x00 to 0x17 consume only 1 byte, so they are reserved for output data
@@ -173,7 +185,7 @@ const data_object_t data_objects[] = {
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
#if CONFIG_HAS_DCDC_CONVERTER
TS_DATA_OBJ_BOOL(0x62, "DcdcEn", &dcdc.enabled,
TS_DATA_OBJ_BOOL(0x62, "DcdcEn", &dcdc.enable,
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
#endif
@@ -183,13 +195,10 @@ const data_object_t data_objects[] = {
#endif
#if CONFIG_HV_TERMINAL_NANOGRID
TS_DATA_OBJ_FLOAT(0x64, "GridSink_V", &grid_terminal.sink_voltage_max, 2,
TS_DATA_OBJ_FLOAT(0x64, "GridSink_V", &hv_bus.sink_voltage_bound, 2,
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
TS_DATA_OBJ_FLOAT(0x65, "GridSrcStart_V", &grid_terminal.src_voltage_start, 2,
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
TS_DATA_OBJ_FLOAT(0x66, "GridSrcStop_V", &grid_terminal.src_voltage_stop, 2,
TS_DATA_OBJ_FLOAT(0x66, "GridSrc_V", &hv_bus.src_voltage_bound, 2,
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
#endif
@@ -207,11 +216,11 @@ const data_object_t data_objects[] = {
TS_OUTPUT, TS_READ_ALL),
// battery related data objects
TS_DATA_OBJ_FLOAT(0x70, "Bat_V", &bat_terminal.bus->voltage, 2,
TS_DATA_OBJ_FLOAT(0x70, "Bat_V", &bat_bus.voltage, 2,
TS_OUTPUT, TS_READ_ALL),
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
TS_DATA_OBJ_FLOAT(0x71, "Solar_V", &solar_terminal.bus->voltage, 2,
TS_DATA_OBJ_FLOAT(0x71, "Solar_V", &solar_bus.voltage, 2,
TS_OUTPUT, TS_READ_ALL),
#endif
@@ -248,7 +257,7 @@ const data_object_t data_objects[] = {
TS_OUTPUT, TS_READ_ALL),
#endif
TS_DATA_OBJ_FLOAT(0x7B, "BatTarget_V", &bat_terminal.sink_voltage_max, 2,
TS_DATA_OBJ_FLOAT(0x7B, "BatTarget_V", &bat_bus.sink_voltage_bound, 2,
TS_OUTPUT, TS_READ_ALL),
TS_DATA_OBJ_FLOAT(0x7C, "BatTarget_A", &bat_terminal.pos_current_limit, 2,
@@ -265,6 +274,11 @@ const data_object_t data_objects[] = {
TS_DATA_OBJ_FLOAT(0x7F, "Load_W", &load_terminal.power, 2,
TS_OUTPUT, TS_READ_ALL),
#if CONFIG_HV_TERMINAL_NANOGRID
TS_DATA_OBJ_FLOAT(0x80, "Grid_V", &hv_bus.voltage, 2,
TS_OUTPUT, TS_READ_ALL),
#endif
TS_DATA_OBJ_UINT32(0x90, "ErrorFlags", &dev_stat.error_flags,
TS_OUTPUT, TS_READ_ALL),