Move voltage control parameters to DcBus class
The sink and source voltage boundaries for droop control and battery charge voltage management are now part of the DcBus class. Also added source and sink current margins, which will be used by the DC/DC for control targets instead of port current limits, which were difficult to synchronize before.
This commit is contained in:
+23
-9
@@ -30,6 +30,18 @@ uint32_t device_id = CONFIG_DEVICE_ID;
|
||||
|
||||
extern uint32_t timestamp;
|
||||
|
||||
#if CONFIG_LV_TERMINAL_BATTERY
|
||||
#define bat_bus lv_bus
|
||||
#elif CONFIG_HV_TERMINAL_BATTERY
|
||||
#define bat_bus hv_bus
|
||||
#endif
|
||||
|
||||
#if CONFIG_HV_TERMINAL_SOLAR
|
||||
#define solar_bus hv_bus
|
||||
#elif CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
|
||||
#define solar_bus lv_bus
|
||||
#endif
|
||||
|
||||
/** Data Objects
|
||||
*
|
||||
* IDs from 0x00 to 0x17 consume only 1 byte, so they are reserved for output data
|
||||
@@ -173,7 +185,7 @@ const data_object_t data_objects[] = {
|
||||
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
TS_DATA_OBJ_BOOL(0x62, "DcdcEn", &dcdc.enabled,
|
||||
TS_DATA_OBJ_BOOL(0x62, "DcdcEn", &dcdc.enable,
|
||||
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
|
||||
#endif
|
||||
|
||||
@@ -183,13 +195,10 @@ const data_object_t data_objects[] = {
|
||||
#endif
|
||||
|
||||
#if CONFIG_HV_TERMINAL_NANOGRID
|
||||
TS_DATA_OBJ_FLOAT(0x64, "GridSink_V", &grid_terminal.sink_voltage_max, 2,
|
||||
TS_DATA_OBJ_FLOAT(0x64, "GridSink_V", &hv_bus.sink_voltage_bound, 2,
|
||||
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
|
||||
|
||||
TS_DATA_OBJ_FLOAT(0x65, "GridSrcStart_V", &grid_terminal.src_voltage_start, 2,
|
||||
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
|
||||
|
||||
TS_DATA_OBJ_FLOAT(0x66, "GridSrcStop_V", &grid_terminal.src_voltage_stop, 2,
|
||||
TS_DATA_OBJ_FLOAT(0x66, "GridSrc_V", &hv_bus.src_voltage_bound, 2,
|
||||
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
|
||||
#endif
|
||||
|
||||
@@ -207,11 +216,11 @@ const data_object_t data_objects[] = {
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
|
||||
// battery related data objects
|
||||
TS_DATA_OBJ_FLOAT(0x70, "Bat_V", &bat_terminal.bus->voltage, 2,
|
||||
TS_DATA_OBJ_FLOAT(0x70, "Bat_V", &bat_bus.voltage, 2,
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
|
||||
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
|
||||
TS_DATA_OBJ_FLOAT(0x71, "Solar_V", &solar_terminal.bus->voltage, 2,
|
||||
TS_DATA_OBJ_FLOAT(0x71, "Solar_V", &solar_bus.voltage, 2,
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
#endif
|
||||
|
||||
@@ -248,7 +257,7 @@ const data_object_t data_objects[] = {
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
#endif
|
||||
|
||||
TS_DATA_OBJ_FLOAT(0x7B, "BatTarget_V", &bat_terminal.sink_voltage_max, 2,
|
||||
TS_DATA_OBJ_FLOAT(0x7B, "BatTarget_V", &bat_bus.sink_voltage_bound, 2,
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
|
||||
TS_DATA_OBJ_FLOAT(0x7C, "BatTarget_A", &bat_terminal.pos_current_limit, 2,
|
||||
@@ -265,6 +274,11 @@ const data_object_t data_objects[] = {
|
||||
TS_DATA_OBJ_FLOAT(0x7F, "Load_W", &load_terminal.power, 2,
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
|
||||
#if CONFIG_HV_TERMINAL_NANOGRID
|
||||
TS_DATA_OBJ_FLOAT(0x80, "Grid_V", &hv_bus.voltage, 2,
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
#endif
|
||||
|
||||
TS_DATA_OBJ_UINT32(0x90, "ErrorFlags", &dev_stat.error_flags,
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
|
||||
|
||||