app: convert power port to C
DcBus and PowerPort become struct dc_bus and struct power_port with prefixed functions instead of member functions. The default member initializers are replaced by dc_bus_init() and power_port_init(). The only non-zero default value is the series multiplier of the bus, which is set to 1 by dc_bus_init() and in the static initializers of the global buses. The optional voltage parameter of the control voltage functions has to be passed explicitly now, 0 still selects the voltage intercept of the bus. LoadOutput and PwmSwitch still inherit from the C struct until they are converted, and initialize it with power_port_init(). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
297fd9e336
commit
3cc24411b5
+10
-6
@@ -30,9 +30,11 @@ LOG_MODULE_REGISTER(load, CONFIG_LOAD_LOG_LEVEL);
|
||||
|
||||
extern DeviceStatus dev_stat;
|
||||
|
||||
LoadOutput::LoadOutput(DcBus *dc_bus, const struct device *sw, int led_pos)
|
||||
: PowerPort(dc_bus), power_switch(sw), led(led_pos)
|
||||
LoadOutput::LoadOutput(struct dc_bus *dc_bus, const struct device *sw, int led_pos)
|
||||
: power_switch(sw), led(led_pos)
|
||||
{
|
||||
power_port_init(this, dc_bus, false);
|
||||
|
||||
state = LOAD_STATE_OFF;
|
||||
|
||||
if (!device_is_ready(power_switch)) {
|
||||
@@ -82,14 +84,16 @@ void LoadOutput::control()
|
||||
flags_set(&error_flags, ERR_LOAD_BUS_SRC_CURRENT);
|
||||
}
|
||||
|
||||
if (bus->voltage < bus->src_control_voltage(disconnect_voltage)) {
|
||||
if (bus->voltage < dc_bus_src_control_voltage(bus, disconnect_voltage)) {
|
||||
flags_set(&error_flags, ERR_LOAD_SHEDDING);
|
||||
lvd_timestamp = uptime();
|
||||
}
|
||||
|
||||
// long-term overvoltage (overvoltage transients are detected as an ADC alert and switch
|
||||
// off the solar input instead of the load output)
|
||||
if (bus->voltage > bus->series_voltage(overvoltage) || bus->voltage > PCB_LS_VOLTAGE_MAX) {
|
||||
if (bus->voltage > dc_bus_series_voltage(bus, overvoltage)
|
||||
|| bus->voltage > PCB_LS_VOLTAGE_MAX)
|
||||
{
|
||||
ov_debounce_counter++;
|
||||
if (ov_debounce_counter > CONFIG_CONTROL_FREQUENCY) {
|
||||
// waited 1s before setting the flag
|
||||
@@ -113,7 +117,7 @@ void LoadOutput::control()
|
||||
// load is off: check if errors are resolved and if load can be switched on
|
||||
|
||||
if (flags_check(&error_flags, ERR_LOAD_SHEDDING)
|
||||
&& bus->voltage > bus->src_control_voltage(reconnect_voltage)
|
||||
&& bus->voltage > dc_bus_src_control_voltage(bus, reconnect_voltage)
|
||||
&& uptime() - lvd_timestamp > lvd_recovery_delay)
|
||||
{
|
||||
flags_clear(&error_flags, ERR_LOAD_SHEDDING);
|
||||
@@ -126,7 +130,7 @@ void LoadOutput::control()
|
||||
}
|
||||
|
||||
if (flags_check(&error_flags, ERR_LOAD_OVERVOLTAGE)
|
||||
&& bus->voltage < (bus->series_voltage(overvoltage) - ov_hysteresis)
|
||||
&& bus->voltage < (dc_bus_series_voltage(bus, overvoltage) - ov_hysteresis)
|
||||
&& bus->voltage < (PCB_LS_VOLTAGE_MAX - ov_hysteresis))
|
||||
{
|
||||
flags_clear(&error_flags, ERR_LOAD_OVERVOLTAGE);
|
||||
|
||||
Reference in New Issue
Block a user