Battery voltage & current filtering to improve charging algorithm
For PWM charge controllers, the topping stage was sometimes very short and the battery did not get fully charged. This commit adds a voltage_filtered and current_filtered member variable to DcBus and PowerPort classes which can hold measurements more heavily filtered (initial time constant setting: 10 seconds). This should fix above issues with the charging algorithm.
This commit is contained in:
+17
@@ -22,6 +22,11 @@ LOG_MODULE_REGISTER(daq, CONFIG_DAQ_LOG_LEVEL);
|
||||
// typical value for Semitec 103AT-5 thermistor: 3435
|
||||
#define NTC_BETA_VALUE 3435
|
||||
|
||||
// filter parameter c for additional battery voltage and current low-pass filter
|
||||
// c = dt / (tau + dt) = 0.1s / (10s + 0.1s)
|
||||
#define LV_BUS_VOLTAGE_FILTER_CONST 0.0099F
|
||||
#define LV_TERMINAL_CURRENT_FILTER_CONST 0.0099F
|
||||
|
||||
#if BOARD_HAS_DCDC
|
||||
static uint16_t dcdc_current_offset_raw;
|
||||
#endif
|
||||
@@ -168,6 +173,15 @@ void daq_update()
|
||||
// calculate lower voltage first, as it is needed for PWM terminal voltage calculation
|
||||
lv_bus.voltage = adc_scaled(ADC_POS(v_low), vref, ADC_GAIN(v_low));
|
||||
|
||||
if (lv_bus.voltage_filtered != 0.0F) {
|
||||
lv_bus.voltage_filtered = LV_BUS_VOLTAGE_FILTER_CONST * lv_bus.voltage +
|
||||
(1.0F - LV_BUS_VOLTAGE_FILTER_CONST) * lv_bus.voltage_filtered;
|
||||
}
|
||||
else {
|
||||
// initialize properly at startup
|
||||
lv_bus.voltage_filtered = lv_bus.voltage;
|
||||
}
|
||||
|
||||
#if BOARD_HAS_DCDC
|
||||
hv_bus.voltage = adc_scaled(ADC_POS(v_high), vref, ADC_GAIN(v_high));
|
||||
#endif
|
||||
@@ -212,6 +226,9 @@ void daq_update()
|
||||
lv_terminal.current = lv_terminal_current;
|
||||
lv_terminal.power = lv_terminal.bus->voltage * lv_terminal.current;
|
||||
|
||||
lv_terminal.current_filtered = LV_TERMINAL_CURRENT_FILTER_CONST * lv_bus.voltage +
|
||||
(1.0F - LV_TERMINAL_CURRENT_FILTER_CONST) * lv_bus.voltage_filtered;
|
||||
|
||||
#if BOARD_HAS_LOAD_OUTPUT
|
||||
load.power = load.bus->voltage * load.current;
|
||||
#endif
|
||||
|
||||