Fixed internal temperature data output

This commit is contained in:
Martin Jaeger
2019-11-06 10:17:49 +01:00
parent b0fe567884
commit 2992cebb81
+1 -2
View File
@@ -36,7 +36,6 @@ const char* const firmware_commit = COMMIT_HASH;
uint32_t device_id = DEVICE_ID; // from config.h
extern uint32_t timestamp;
float internal_temp;
/** Data Objects
*
@@ -131,7 +130,7 @@ const data_object_t data_objects[] = {
{0x73, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(load_terminal.current), "Load_A"},
{0x74, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 1, (void*) &(charger.bat_temperature), "Bat_degC"},
{0x75, TS_OUTPUT, TS_READ_ALL, TS_T_BOOL, 0, (void*) &(charger.ext_temp_sensor), "BatTempExt"},
{0x76, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 1, (void*) &(internal_temp), "Int_degC"},
{0x76, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 1, (void*) &(dev_stat.internal_temp), "Int_degC"},
#if defined(PIN_ADC_TEMP_FETS) && FEATURE_DCDC_CONVERTER
{0x77, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 1, (void*) &(dcdc.temp_mosfets), "Mosfet_degC"},
#endif