LogData renamed to DeviceStatus / dev_stat
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status is more generic and now contains also the internal temperature measurement.
This commit is contained in:
+6
-7
@@ -61,8 +61,7 @@ volatile uint16_t adc_readings[NUM_ADC_CH] = {0};
|
||||
volatile uint32_t adc_filtered[NUM_ADC_CH] = {0};
|
||||
//volatile int num_adc_conversions;
|
||||
|
||||
extern LogData log_data;
|
||||
extern float internal_temp;
|
||||
extern DeviceStatus dev_stat;
|
||||
|
||||
void calibrate_current_sensors()
|
||||
{
|
||||
@@ -173,15 +172,15 @@ void update_measurements()
|
||||
|
||||
// internal MCU temperature
|
||||
uint16_t adcval = (adc_filtered[ADC_POS_TEMP_MCU] >> (4 + ADC_FILTER_CONST)) * vcc / VREFINT_VALUE;
|
||||
internal_temp = (TSENSE_CAL2_VALUE - TSENSE_CAL1_VALUE) /
|
||||
dev_stat.internal_temp = (TSENSE_CAL2_VALUE - TSENSE_CAL1_VALUE) /
|
||||
(TSENSE_CAL2 - TSENSE_CAL1) * (adcval - TSENSE_CAL1) + TSENSE_CAL1_VALUE;
|
||||
|
||||
if (internal_temp > 80) {
|
||||
log_data.error_flags |= 1U << ERR_INT_OVERTEMP;
|
||||
if (dev_stat.internal_temp > 80) {
|
||||
dev_stat.error_flags |= 1U << ERR_INT_OVERTEMP;
|
||||
}
|
||||
else if (internal_temp < 70 && (log_data.error_flags & (1U << ERR_INT_OVERTEMP))) {
|
||||
else if (dev_stat.internal_temp < 70 && (dev_stat.error_flags & (1U << ERR_INT_OVERTEMP))) {
|
||||
// remove error flag with hysteresis of 10°C
|
||||
log_data.error_flags &= ~(1U << ERR_INT_OVERTEMP);
|
||||
dev_stat.error_flags &= ~(1U << ERR_INT_OVERTEMP);
|
||||
}
|
||||
// else: keep previous setting
|
||||
}
|
||||
|
||||
Reference in New Issue