LogData renamed to DeviceStatus / dev_stat

Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
This commit is contained in:
Martin Jaeger
2019-11-01 09:54:01 +01:00
parent af4af04697
commit 22f9138a15
17 changed files with 359 additions and 359 deletions
+6 -7
View File
@@ -61,8 +61,7 @@ volatile uint16_t adc_readings[NUM_ADC_CH] = {0};
volatile uint32_t adc_filtered[NUM_ADC_CH] = {0};
//volatile int num_adc_conversions;
extern LogData log_data;
extern float internal_temp;
extern DeviceStatus dev_stat;
void calibrate_current_sensors()
{
@@ -173,15 +172,15 @@ void update_measurements()
// internal MCU temperature
uint16_t adcval = (adc_filtered[ADC_POS_TEMP_MCU] >> (4 + ADC_FILTER_CONST)) * vcc / VREFINT_VALUE;
internal_temp = (TSENSE_CAL2_VALUE - TSENSE_CAL1_VALUE) /
dev_stat.internal_temp = (TSENSE_CAL2_VALUE - TSENSE_CAL1_VALUE) /
(TSENSE_CAL2 - TSENSE_CAL1) * (adcval - TSENSE_CAL1) + TSENSE_CAL1_VALUE;
if (internal_temp > 80) {
log_data.error_flags |= 1U << ERR_INT_OVERTEMP;
if (dev_stat.internal_temp > 80) {
dev_stat.error_flags |= 1U << ERR_INT_OVERTEMP;
}
else if (internal_temp < 70 && (log_data.error_flags & (1U << ERR_INT_OVERTEMP))) {
else if (dev_stat.internal_temp < 70 && (dev_stat.error_flags & (1U << ERR_INT_OVERTEMP))) {
// remove error flag with hysteresis of 10°C
log_data.error_flags &= ~(1U << ERR_INT_OVERTEMP);
dev_stat.error_flags &= ~(1U << ERR_INT_OVERTEMP);
}
// else: keep previous setting
}