Improved load overcurrent and overvoltage diagnosis and protection
This commit is contained in:
+3
-4
@@ -55,8 +55,6 @@ extern ThingSet ts; // defined in data_objects.cpp
|
||||
|
||||
time_t timestamp; // current unix timestamp (independent of time(NULL), as it is user-configurable)
|
||||
|
||||
#define CONTROL_FREQUENCY 10 // Hz (higher frequency caused issues with MPPT control)
|
||||
|
||||
//----------------------------------------------------------------------------
|
||||
// function prototypes
|
||||
|
||||
@@ -76,14 +74,15 @@ void system_control() // called by control timer (see hardware.cpp)
|
||||
|
||||
#ifdef CHARGER_TYPE_PWM
|
||||
pwm_switch_control(&pwm_switch, &hs_port, bat_port);
|
||||
leds_set_charging(pwm_switch_enabled());
|
||||
#else
|
||||
// control PWM of the DC/DC according to hs and ls port settings
|
||||
// (this function includes MPPT algorithm)
|
||||
dcdc_control(&dcdc, &hs_port, &ls_port);
|
||||
leds_set_charging(half_bridge_enabled());
|
||||
#endif
|
||||
|
||||
load_check_overcurrent(&load);
|
||||
update_dcdc_led(half_bridge_enabled());
|
||||
load_control(&load);
|
||||
|
||||
if (counter % CONTROL_FREQUENCY == 0) {
|
||||
// called once per second (this timer is much more accurate than time(NULL) based on LSI)
|
||||
|
||||
Reference in New Issue