@@ -78,9 +78,9 @@ const data_object_t data_objects[] = {
{0x31, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_FLOAT32, 2, (void*) &(bat_conf_user.voltage_recharge), "BatRecharge_V"},
{0x32, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_FLOAT32, 2, (void*) &(bat_conf_user.voltage_absolute_min), "BatAbsMin_V"},
{0x33, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_FLOAT32, 1, (void*) &(bat_conf_user.charge_current_max), "BatChgMax_A"},
{0x34, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_FLOAT32, 2, (void*) &(bat_conf_user.voltage_max), "BatTarget_V"},
{0x35, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_FLOAT32, 1, (void*) &(bat_conf_user.current_cutoff_CV), "BatCutoff_A"},
{0x36, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_INT32, 0, (void*) &(bat_conf_user.time_limit_CV), "BatCutoff_s"},
{0x34, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_FLOAT32, 2, (void*) &(bat_conf_user.voltage_topping), "BatTarget_V"},
{0x35, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_FLOAT32, 1, (void*) &(bat_conf_user.current_cutoff_topping), "BatCutoff_A"},
{0x36, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_INT32, 0, (void*) &(bat_conf_user.time_limit_topping), "BatCutoff_s"},
{0x37, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_BOOL, 0, (void*) &(bat_conf_user.trickle_enabled), "TrickleEn"},
{0x38, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_FLOAT32, 2, (void*) &(bat_conf_user.voltage_trickle), "Trickle_V"},
{0x39, TS_CAT_CONF, TS_ACCESS_READ | TS_ACCESS_WRITE, TS_T_INT32, 0, (void*) &(bat_conf_user.time_trickle_recharge), "TrickleRecharge_s"},
@@ -180,6 +180,7 @@ const data_object_t data_objects[] = {
{0xB7, TS_CAT_REC, TS_ACCESS_READ, TS_T_INT32, 1, (void*) &(log_data.bat_temp_max), "BatMax_degC"},
{0xB8, TS_CAT_REC, TS_ACCESS_READ, TS_T_INT32, 1, (void*) &(log_data.int_temp_max), "IntMax_degC"},
{0xB9, TS_CAT_REC, TS_ACCESS_READ, TS_T_INT32, 1, (void*) &(log_data.mosfet_temp_max), "MosfetMax_degC"},
{0xBA, TS_CAT_REC, TS_ACCESS_READ, TS_T_UINT32, 1, (void*) &(log_data.error_flags), "ErrorFlags"},
// CALIBRATION DATA ///////////////////////////////////////////////////////
// using IDs >= 0xD0