Port configuration based on Kconfig implemented

This commit is contained in:
Martin Jaeger
2020-01-06 19:16:44 +01:00
parent 7bd9bdeafd
commit 16ca793bb3
19 changed files with 158 additions and 108 deletions
+5 -5
View File
@@ -27,7 +27,7 @@ void DeviceStatus::update_energy()
static uint32_t bat_chg_total_Wh_prev = bat_chg_total_Wh;
static uint32_t bat_dis_total_Wh_prev = bat_dis_total_Wh;
#ifdef SOLAR_TERMINAL
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
if (solar_terminal.voltage < bat_terminal.voltage) {
seconds_zero_solar += 1;
}
@@ -54,7 +54,7 @@ void DeviceStatus::update_energy()
(bat_terminal.pos_energy_Wh > 0 ? bat_terminal.pos_energy_Wh : 0);
bat_dis_total_Wh = bat_dis_total_Wh_prev +
(bat_terminal.neg_energy_Wh > 0 ? bat_terminal.neg_energy_Wh : 0);
#ifdef SOLAR_TERMINAL
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
solar_in_total_Wh = solar_in_total_Wh_prev +
(solar_terminal.neg_energy_Wh > 0 ? solar_terminal.neg_energy_Wh : 0);
#endif
@@ -68,13 +68,13 @@ void DeviceStatus::update_min_max_values()
battery_voltage_max = bat_terminal.voltage;
}
#ifdef SOLAR_TERMINAL
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
if (solar_terminal.voltage > solar_voltage_max) {
solar_voltage_max = solar_terminal.voltage;
}
#endif
#if FEATURE_DCDC_CONVERTER
#if CONFIG_HAS_DCDC_CONVERTER
if (dcdc.lvs->current > dcdc_current_max) {
dcdc_current_max = dcdc.lvs->current;
}
@@ -88,7 +88,7 @@ void DeviceStatus::update_min_max_values()
load_current_max = load_terminal.current;
}
#ifdef SOLAR_TERMINAL
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
if (-solar_terminal.power > solar_power_max_day) {
solar_power_max_day = -solar_terminal.power;
if (solar_power_max_day > solar_power_max_total) {