From 0c20545f88ae4ac0dd43f6340f727614ec1d6a9f Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?Martin=20J=C3=A4ger?= Date: Tue, 18 Feb 2020 16:33:24 +0100 Subject: [PATCH] Differentiate between src and sink droop res again Necessary for improved load disconnect switch behavior. --- src/bat_charger.cpp | 22 ++++++++++----------- src/dcdc.cpp | 4 ++-- src/power_port.cpp | 5 ++++- src/power_port.h | 39 ++++++++++++++++++++++++++++++++++---- src/pwm_switch.cpp | 7 +++---- test/tests_bat_charger.cpp | 12 ++++++------ 6 files changed, 60 insertions(+), 29 deletions(-) diff --git a/src/bat_charger.cpp b/src/bat_charger.cpp index 6e54902..5a9502a 100644 --- a/src/bat_charger.cpp +++ b/src/bat_charger.cpp @@ -293,7 +293,7 @@ void Charger::discharge_control(BatConf *bat_conf) if (port->neg_current_limit < 0) { // discharging currently allowed. see if that's still valid: if (port->bus->voltage < num_batteries * - (bat_conf->voltage_load_disconnect - port->current * port->bus->droop_res)) + port->bus->src_droop_voltage(bat_conf->voltage_load_disconnect)) { uv_debounce_counter++; if (uv_debounce_counter >= 3) { // 3s in undervoltage --> switch off @@ -334,7 +334,7 @@ void Charger::discharge_control(BatConf *bat_conf) else { // discharging currently not allowed. should we allow it? if (port->bus->voltage >= num_batteries * - (bat_conf->voltage_load_reconnect - port->current * port->bus->droop_res) + port->bus->src_droop_voltage(bat_conf->voltage_load_reconnect) && bat_temperature < bat_conf->discharge_temp_max - 1 && bat_temperature > bat_conf->discharge_temp_min + 1) { @@ -395,9 +395,7 @@ void Charger::charge_control(BatConf *bat_conf) port->bus->sink_voltage_bound = num_batteries * (bat_conf->topping_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); - if (port->bus->voltage > - port->bus->droop_voltage(port->bus->sink_voltage_bound)) - { + if (port->bus->voltage > port->bus->sink_droop_voltage()) { target_voltage_timer = 0; enter_state(CHG_STATE_TOPPING); } @@ -408,9 +406,7 @@ void Charger::charge_control(BatConf *bat_conf) port->bus->sink_voltage_bound = num_batteries * (bat_conf->topping_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); - if (port->bus->voltage >= - port->bus->droop_voltage(port->bus->sink_voltage_bound) - 0.05F) - { + if (port->bus->voltage >= port->bus->sink_droop_voltage() - 0.05F) { // battery is full if topping target voltage is still reached (i.e. sufficient // solar power available) and time limit or cut-off current reached if (port->current < bat_conf->topping_current_cutoff || @@ -457,9 +453,7 @@ void Charger::charge_control(BatConf *bat_conf) port->bus->sink_voltage_bound = num_batteries * (bat_conf->trickle_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); - if (port->bus->voltage >= num_batteries * - (port->bus->sink_voltage_bound - port->current * port->bus->droop_res)) - { + if (port->bus->voltage >= port->bus->sink_droop_voltage()) { time_target_voltage_reached = uptime(); } @@ -512,5 +506,9 @@ void Charger::init_terminal(BatConf *bat) port->pos_current_limit = bat->charge_current_max; // negative sign for compensation of actual resistance - port->bus->droop_res = -(bat->internal_resistance + bat->wire_resistance) * num_batteries; + port->bus->sink_droop_res = -bat->wire_resistance; + + // in discharging direction also include battery internal resistance for current-compensation + // of voltage setpoints + port->bus->src_droop_res = -bat->wire_resistance - bat->internal_resistance * num_batteries; } diff --git a/src/dcdc.cpp b/src/dcdc.cpp index 8a96f4f..1a18ac4 100644 --- a/src/dcdc.cpp +++ b/src/dcdc.cpp @@ -78,7 +78,7 @@ int Dcdc::duty_cycle_delta() // swith off after 10s low power or negative power (if not in nanogrid mode) pwr_inc_goal = 0; } - else if (out->bus->voltage > out->bus->droop_voltage(out->bus->sink_voltage_bound)) { + else if (out->bus->voltage > out->bus->sink_droop_voltage()) { // output voltage target reached state = DCDC_STATE_CV; pwr_inc_goal = -1; // decrease output power @@ -90,7 +90,7 @@ int Dcdc::duty_cycle_delta() } else if (fabs(lvs->current) > ls_current_max // current above hardware maximum || temp_mosfets > 80 // temperature limits exceeded - || (in->bus->voltage < in->bus->droop_voltage(in->bus->src_voltage_bound) + || (in->bus->voltage < in->bus->src_droop_voltage() && out->current > 0.1) // input voltage below limit || in->current < in->neg_current_limit) // input current (negative signs) limit exceeded { diff --git a/src/power_port.cpp b/src/power_port.cpp index edfc18b..b12377a 100644 --- a/src/power_port.cpp +++ b/src/power_port.cpp @@ -16,7 +16,10 @@ void PowerPort::init_nanogrid() { pos_current_limit = 5.0; neg_current_limit = -5.0; - bus->droop_res = 0.1; // 1 Ohm means 1V change of target voltage per amp + + // 1 Ohm means 1V change of target voltage per amp, same droop for both current directions. + bus->sink_droop_res = 0.1; + bus->src_droop_res = 0.1; // also initialize the connected bus bus->src_voltage_bound = 30.0; // starting buck mode above this point diff --git a/src/power_port.h b/src/power_port.h index fd00a92..a4e3a4f 100644 --- a/src/power_port.h +++ b/src/power_port.h @@ -46,11 +46,18 @@ public: float src_voltage_bound; /** - * Droop resistance to adjust voltage bounds depending on actual current + * Droop resistance to adjust voltage bounds for current in sourcing direction * * control voltage = nominal voltage - droop_res * current */ - float droop_res; + float src_droop_res; + + /** + * Droop resistance to adjust voltage bounds for current in sinking direction + * + * control voltage = nominal voltage - droop_res * current + */ + float sink_droop_res; /** * Pointer to current measurement that is used to determine the droop. This is typically the @@ -70,10 +77,34 @@ public: */ float src_current_margin; - inline float droop_voltage(float v0) + /** + * Calculate current-compensated voltage based on bus reference current + * + * @param voltage_zero_current Voltage at zero current (without droop). If this parameter is + * left empty, the src_voltage_bound is considered. + */ + inline float src_droop_voltage(float voltage_zero_current = 0) { + float v0 = (voltage_zero_current == 0) ? src_voltage_bound : voltage_zero_current; if (ref_current != nullptr) { - return v0 - droop_res * (*ref_current); + return v0 - src_droop_res * (*ref_current); + } + else { + return v0; + } + } + + /** + * Calculate current-compensated voltage based on bus reference current + * + * @param voltage_zero_current Voltage at zero current (without droop). If this parameter is + * left empty, the sink_voltage_bound is considered. + */ + inline float sink_droop_voltage(float voltage_zero_current = 0) + { + float v0 = (voltage_zero_current == 0) ? sink_voltage_bound : voltage_zero_current; + if (ref_current != nullptr) { + return v0 - sink_droop_res * (*ref_current); } else { return v0; diff --git a/src/pwm_switch.cpp b/src/pwm_switch.cpp index 78b9aa5..6ab3200 100644 --- a/src/pwm_switch.cpp +++ b/src/pwm_switch.cpp @@ -179,10 +179,9 @@ void PwmSwitch::control() off_timestamp = uptime(); print_info("PWM charger stop.\n"); } - else if (bus->voltage > (bus->sink_voltage_bound - - bus->droop_res * current) // voltage above target - || current < neg_current_limit // port current limit exceeded - || current < -PWM_CURRENT_MAX) // PCB current limit exceeded + else if (bus->voltage > bus->sink_droop_voltage() // bus voltage above target + || current < neg_current_limit // port current limit exceeded + || current < -PWM_CURRENT_MAX) // PCB current limit exceeded { // decrease power, as limits were reached diff --git a/test/tests_bat_charger.cpp b/test/tests_bat_charger.cpp index 96fff5b..56dbf00 100644 --- a/test/tests_bat_charger.cpp +++ b/test/tests_bat_charger.cpp @@ -95,7 +95,7 @@ void stop_topping_after_time_limit() charger.target_voltage_timer = bat_conf.topping_duration - 1; bat_terminal.current = bat_conf.topping_current_cutoff + 0.1; bat_terminal.bus->voltage = bat_conf.topping_voltage - - bat_terminal.current * bat_terminal.bus->droop_res + 0.1; + bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state); @@ -112,7 +112,7 @@ void stop_topping_at_cutoff_current() charger.target_voltage_timer = 0; bat_terminal.current = bat_conf.topping_current_cutoff - 0.1; bat_terminal.bus->voltage = bat_conf.topping_voltage - - bat_terminal.current * bat_terminal.bus->droop_res + 0.1; + bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state); } @@ -125,7 +125,7 @@ void trickle_to_idle_for_li_ion() charger.time_state_changed = time(NULL) - 1; bat_terminal.current = bat_conf.topping_current_cutoff - 0.1; bat_terminal.bus->voltage = bat_conf.topping_voltage - - bat_terminal.current * bat_terminal.bus->droop_res + 0.1; + bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state); } @@ -176,7 +176,7 @@ void trickle_to_equalization_if_enabled_and_time_limit_reached() charger.time_state_changed = time(NULL) - 1; bat_terminal.current = bat_conf.topping_current_cutoff - 0.1; bat_terminal.bus->voltage = bat_conf.topping_voltage - - bat_terminal.current * bat_terminal.bus->droop_res + 0.1; + bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state); } @@ -192,7 +192,7 @@ void trickle_to_equalization_if_enabled_and_deep_dis_limit_reached() charger.time_state_changed = time(NULL) - 1; bat_terminal.current = bat_conf.topping_current_cutoff - 0.1; bat_terminal.bus->voltage = bat_conf.topping_voltage - - bat_terminal.current * bat_terminal.bus->droop_res + 0.1; + bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state); } @@ -204,7 +204,7 @@ void stop_equalization_after_time_limit() charger.time_state_changed = time(NULL) - bat_conf.equalization_duration + 1; bat_terminal.bus->voltage = bat_conf.equalization_voltage - - bat_terminal.current * bat_terminal.bus->droop_res + 0.1; + bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);