Rename src/sink_voltage_bound to _intercept
These variables define the voltage at zero current, which is the y axis intercept of the droop curve (voltage vs. current). As they do not always specifiy minimum or maximum boundary depending on the sign of the droop resistance, intercept is a more suitable name.
This commit is contained in:
+4
-4
@@ -33,8 +33,8 @@ static void load_init(LoadOutput *l, bool on = false, int num_batteries = 1)
|
||||
l->pos_current_limit = 10;
|
||||
l->bus->series_multiplier = num_batteries;
|
||||
l->bus->voltage = 14 * num_batteries;
|
||||
l->bus->sink_voltage_bound = 14.4;
|
||||
l->bus->src_voltage_bound = 12;
|
||||
l->bus->sink_voltage_intercept = 14.4;
|
||||
l->bus->src_voltage_intercept = 12;
|
||||
l->bus->sink_current_margin = 10;
|
||||
l->bus->src_current_margin = -10;
|
||||
l->junction_temperature = 25;
|
||||
@@ -93,7 +93,7 @@ void control_on_to_off_overvoltage()
|
||||
LoadOutput load_out(&bus, &load_drv_set, &load_drv_init);
|
||||
load_init(&load_out, true);
|
||||
|
||||
bus.voltage = bus.sink_voltage_bound + 0.6;
|
||||
bus.voltage = bus.sink_voltage_intercept + 0.6;
|
||||
|
||||
// increase debounce counter to 1 before limit
|
||||
for (int i = 0; i < CONFIG_CONTROL_FREQUENCY; i++) {
|
||||
@@ -114,7 +114,7 @@ void control_on_to_off_overvoltage_dual_battery()
|
||||
LoadOutput load_out(&bus, &load_drv_set, &load_drv_init);
|
||||
load_init(&load_out, true, 2);
|
||||
|
||||
bus.voltage = (bus.sink_voltage_bound + 0.6) * bus.series_multiplier;
|
||||
bus.voltage = (bus.sink_voltage_intercept + 0.6) * bus.series_multiplier;
|
||||
|
||||
// increase debounce counter to 1 before limit
|
||||
for (int i = 0; i < CONFIG_CONTROL_FREQUENCY; i++) {
|
||||
|
||||
Reference in New Issue