Rename src/sink_voltage_bound to _intercept
These variables define the voltage at zero current, which is the y axis intercept of the droop curve (voltage vs. current). As they do not always specifiy minimum or maximum boundary depending on the sign of the droop resistance, intercept is a more suitable name.
This commit is contained in:
+10
-10
@@ -462,7 +462,7 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
&& bat_temperature < bat_conf->charge_temp_max - 1
|
||||
&& bat_temperature > bat_conf->charge_temp_min + 1)
|
||||
{
|
||||
port->bus->sink_voltage_bound = bat_conf->topping_voltage +
|
||||
port->bus->sink_voltage_intercept = bat_conf->topping_voltage +
|
||||
bat_conf->temperature_compensation * (bat_temperature - 25);
|
||||
port->pos_current_limit = bat_conf->charge_current_max;
|
||||
full = false;
|
||||
@@ -475,7 +475,7 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
}
|
||||
case CHG_STATE_BULK: {
|
||||
// continuously adjust voltage setting for temperature compensation
|
||||
port->bus->sink_voltage_bound = bat_conf->topping_voltage +
|
||||
port->bus->sink_voltage_intercept = bat_conf->topping_voltage +
|
||||
bat_conf->temperature_compensation * (bat_temperature - 25);
|
||||
|
||||
if (port->bus->voltage > port->bus->sink_control_voltage()) {
|
||||
@@ -486,7 +486,7 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
}
|
||||
case CHG_STATE_TOPPING: {
|
||||
// continuously adjust voltage setting for temperature compensation
|
||||
port->bus->sink_voltage_bound = bat_conf->topping_voltage +
|
||||
port->bus->sink_voltage_intercept = bat_conf->topping_voltage +
|
||||
bat_conf->temperature_compensation * (bat_temperature - 25);
|
||||
|
||||
if (port->bus->voltage >= port->bus->sink_control_voltage() - 0.05F) {
|
||||
@@ -515,12 +515,12 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
num_deep_discharges - deep_dis_last_equalization
|
||||
>= bat_conf->equalization_trigger_deep_cycles))
|
||||
{
|
||||
port->bus->sink_voltage_bound = bat_conf->equalization_voltage;
|
||||
port->bus->sink_voltage_intercept = bat_conf->equalization_voltage;
|
||||
port->pos_current_limit = bat_conf->equalization_current_limit;
|
||||
enter_state(CHG_STATE_EQUALIZATION);
|
||||
}
|
||||
else if (bat_conf->trickle_enabled) {
|
||||
port->bus->sink_voltage_bound = bat_conf->trickle_voltage +
|
||||
port->bus->sink_voltage_intercept = bat_conf->trickle_voltage +
|
||||
bat_conf->temperature_compensation * (bat_temperature - 25);
|
||||
enter_state(CHG_STATE_TRICKLE);
|
||||
}
|
||||
@@ -533,7 +533,7 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
}
|
||||
case CHG_STATE_TRICKLE: {
|
||||
// continuously adjust voltage setting for temperature compensation
|
||||
port->bus->sink_voltage_bound = bat_conf->trickle_voltage +
|
||||
port->bus->sink_voltage_intercept = bat_conf->trickle_voltage +
|
||||
bat_conf->temperature_compensation * (bat_temperature - 25);
|
||||
|
||||
if (port->bus->voltage >= port->bus->sink_control_voltage()) {
|
||||
@@ -553,7 +553,7 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
}
|
||||
case CHG_STATE_EQUALIZATION: {
|
||||
// continuously adjust voltage setting for temperature compensation
|
||||
port->bus->sink_voltage_bound = bat_conf->equalization_voltage +
|
||||
port->bus->sink_voltage_intercept = bat_conf->equalization_voltage +
|
||||
bat_conf->temperature_compensation * (bat_temperature - 25);
|
||||
|
||||
// current or time limit for equalization reached
|
||||
@@ -566,7 +566,7 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
discharged_Ah = 0; // reset coulomb counter again
|
||||
|
||||
if (bat_conf->trickle_enabled) {
|
||||
port->bus->sink_voltage_bound = bat_conf->trickle_voltage +
|
||||
port->bus->sink_voltage_intercept = bat_conf->trickle_voltage +
|
||||
bat_conf->temperature_compensation * (bat_temperature - 25);
|
||||
enter_state(CHG_STATE_TRICKLE);
|
||||
}
|
||||
@@ -582,8 +582,8 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
|
||||
void Charger::init_terminal(BatConf *bat) const
|
||||
{
|
||||
port->bus->sink_voltage_bound = bat->topping_voltage;
|
||||
port->bus->src_voltage_bound = bat->voltage_load_disconnect;
|
||||
port->bus->sink_voltage_intercept = bat->topping_voltage;
|
||||
port->bus->src_voltage_intercept = bat->voltage_load_disconnect;
|
||||
|
||||
port->neg_current_limit = -bat->discharge_current_max;
|
||||
port->pos_current_limit = bat->charge_current_max;
|
||||
|
||||
Reference in New Issue
Block a user