PowerPort added to store current independent from DC bus type

The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
This commit is contained in:
Martin Jaeger
2019-10-20 14:52:35 +02:00
parent d7ed3cdd13
commit 0399c4e877
25 changed files with 860 additions and 823 deletions
+11 -19
View File
@@ -1,26 +1,18 @@
#include "tests.h"
#include "bat_charger.h"
#include "dc_bus.h"
#include "log.h"
#include <time.h>
#include <stdio.h>
#include <math.h>
extern BatConf bat_conf;
extern Charger charger;
extern DcBus *solar_terminal;
extern DcBus *bat_terminal;
extern DcBus load_terminal;
extern LoadOutput load;
extern Dcdc dcdc;
extern LogData log_data;
#include "main.h"
extern PowerPort *solar_terminal;
extern PowerPort *bat_terminal;
void reset_counters_at_start_of_day()
{
solar_terminal->voltage = bat_terminal->voltage - 1;
solar_terminal->bus->voltage = bat_terminal->bus->voltage - 1;
log_data.day_counter = 0;
@@ -48,7 +40,7 @@ void reset_counters_at_start_of_day()
TEST_ASSERT_EQUAL(0, log_data.day_counter);
// now solar power comes back
solar_terminal->voltage = bat_terminal->voltage + 1;
solar_terminal->bus->voltage = bat_terminal->bus->voltage + 1;
log_update_energy(&log_data, solar_terminal, bat_terminal, &load_terminal);
// day counter should be increased and daily energy counters reset
@@ -61,28 +53,28 @@ void reset_counters_at_start_of_day()
void log_new_solar_voltage_max()
{
solar_terminal->voltage = 40;
solar_terminal->bus->voltage = 40;
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
TEST_ASSERT_EQUAL(40, log_data.solar_voltage_max);
}
void log_new_bat_voltage_max()
{
bat_terminal->voltage = 31;
bat_terminal->bus->voltage = 31;
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
TEST_ASSERT_EQUAL(31, log_data.battery_voltage_max);
}
void log_new_dcdc_current_max()
{
dcdc.lv_bus->current = 21;
dcdc.lvs->current = 21;
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
TEST_ASSERT_EQUAL(21, log_data.dcdc_current_max);
}
void log_new_load_current_max()
{
load.terminal->current = 21;
load.port->current = 21;
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
TEST_ASSERT_EQUAL(21, log_data.load_current_max);
}
@@ -97,7 +89,7 @@ void log_solar_power_max()
void log_load_power_max()
{
load.terminal->power = 50;
load.port->power = 50;
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
TEST_ASSERT_EQUAL(50, log_data.load_power_max_day);
TEST_ASSERT_EQUAL(50, log_data.load_power_max_total);