PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each connection to a junction, as described in issue #50. With this commit, also some structs were converted to C++ classes to improve readibility of the code and make sure that pointers (e.g. to PowerPort objects) are always assigned during initialization.
This commit is contained in:
+38
-29
@@ -44,19 +44,31 @@
|
||||
|
||||
Serial serial(PIN_SWD_TX, PIN_SWD_RX, "serial", 115200);
|
||||
|
||||
Dcdc dcdc = {};
|
||||
DcBus hv_terminal = {}; // high voltage terminal (solar for typical MPPT)
|
||||
DcBus lv_bus_int = {}; // internal low voltage side of DC/DC converter
|
||||
DcBus lv_terminal = {}; // low voltage terminal (battery for typical MPPT)
|
||||
DcBus load_terminal = {}; // load terminal
|
||||
DcBus *bat_terminal = NULL; // pointer to terminal where battery is connected
|
||||
DcBus *solar_terminal = NULL; // pointer to above terminal where solar panel is connected
|
||||
DcBus hv_bus;
|
||||
PowerPort hv_terminal(&hv_bus); // high voltage terminal (solar for typical MPPT)
|
||||
PowerPort dcdc_port_hv(&hv_bus); // internal high voltage side port of DC/DC converter
|
||||
|
||||
DcBus lv_bus;
|
||||
PowerPort dcdc_port_lv(&lv_bus); // internal low voltage side of DC/DC converter
|
||||
PowerPort lv_terminal(&lv_bus); // low voltage terminal (battery for typical MPPT)
|
||||
PowerPort load_terminal(&lv_bus); // load terminal (also connected to lv_bus)
|
||||
|
||||
PowerPort *bat_terminal = NULL;
|
||||
PowerPort *solar_terminal = NULL;
|
||||
PowerPort *grid_terminal = NULL;
|
||||
|
||||
Dcdc dcdc(&dcdc_port_hv, &dcdc_port_lv, DCDC_MODE_INIT);
|
||||
|
||||
PwmSwitch pwm_switch = {}; // only necessary for PWM charger
|
||||
|
||||
Charger charger(&lv_terminal);
|
||||
LoadOutput load(&load_terminal);
|
||||
|
||||
BatConf bat_conf; // actual (used) battery configuration
|
||||
BatConf bat_conf_user; // temporary storage where the user can write to
|
||||
Charger charger; // charger state information
|
||||
LoadOutput load;
|
||||
|
||||
LogData log_data;
|
||||
|
||||
extern ThingSet ts; // defined in data_objects.cpp
|
||||
|
||||
time_t timestamp; // current unix timestamp (independent of time(NULL), as it is user-configurable)
|
||||
@@ -78,11 +90,11 @@ void system_control()
|
||||
#else
|
||||
// control PWM of the DC/DC according to hs and ls port settings
|
||||
// (this function includes MPPT algorithm)
|
||||
dcdc_control(&dcdc);
|
||||
dcdc.control();
|
||||
leds_set_charging(half_bridge_enabled());
|
||||
#endif
|
||||
|
||||
load_control(&load, bat_conf.voltage_absolute_max * charger.num_batteries);
|
||||
load.control(bat_conf.voltage_absolute_max * charger.num_batteries);
|
||||
|
||||
if (counter % CONTROL_FREQUENCY == 0) {
|
||||
// called once per second (this timer is much more accurate than time(NULL) based on LSI)
|
||||
@@ -90,12 +102,12 @@ void system_control()
|
||||
timestamp++;
|
||||
counter = 0;
|
||||
// energy + soc calculation must be called exactly once per second
|
||||
dc_bus_energy_balance(&hv_terminal);
|
||||
dc_bus_energy_balance(&lv_terminal);
|
||||
dc_bus_energy_balance(&load_terminal);
|
||||
hv_terminal.energy_balance();
|
||||
lv_terminal.energy_balance();
|
||||
load_terminal.energy_balance();
|
||||
log_update_energy(&log_data, &hv_terminal, &lv_terminal, &load_terminal);
|
||||
log_update_min_max_values(&log_data, &dcdc, &charger, &load, &hv_terminal, &lv_terminal, &load_terminal);
|
||||
battery_update_soc(&bat_conf, &charger, bat_terminal);
|
||||
charger.update_soc(&bat_conf);
|
||||
}
|
||||
counter++;
|
||||
}
|
||||
@@ -108,14 +120,10 @@ int main()
|
||||
|
||||
battery_conf_init(&bat_conf, BATTERY_TYPE, BATTERY_NUM_CELLS, BATTERY_CAPACITY);
|
||||
battery_conf_overwrite(&bat_conf, &bat_conf_user); // initialize conf_user with same values
|
||||
charger_init(&charger);
|
||||
|
||||
load_init(&load, &lv_bus_int, &load_terminal);
|
||||
|
||||
#ifdef CHARGER_TYPE_PWM
|
||||
pwm_switch_init(&pwm_switch);
|
||||
#else // MPPT
|
||||
dcdc_init(&dcdc, &hv_terminal, &lv_bus_int, DCDC_MODE_INIT);
|
||||
half_bridge_init(PWM_FREQUENCY, PWM_DEADTIME, 12 / dcdc.hs_voltage_max, 0.97); // lower duty limit might have to be adjusted dynamically depending on LS voltage
|
||||
#endif
|
||||
|
||||
@@ -142,28 +150,29 @@ int main()
|
||||
#ifdef CHARGER_TYPE_PWM
|
||||
bat_terminal = &lv_terminal;
|
||||
solar_terminal = &hv_terminal;
|
||||
dc_bus_init_solar(solar_terminal, PWM_CURRENT_MAX);
|
||||
solar_terminal->init_solar(PWM_CURRENT_MAX);
|
||||
#else
|
||||
// Setup of DC/DC power stage
|
||||
switch(dcdc.mode) {
|
||||
case MODE_NANOGRID:
|
||||
bat_terminal = &lv_terminal;
|
||||
dc_bus_init_nanogrid(&hv_terminal);
|
||||
hv_terminal.init_nanogrid();
|
||||
break;
|
||||
case MODE_MPPT_BUCK: // typical MPPT charge controller operation
|
||||
bat_terminal = &lv_terminal;
|
||||
solar_terminal = &hv_terminal;
|
||||
dc_bus_init_solar(solar_terminal, DCDC_CURRENT_MAX);
|
||||
solar_terminal->init_solar(DCDC_CURRENT_MAX);
|
||||
break;
|
||||
case MODE_MPPT_BOOST: // for charging of e-bike battery via solar panel
|
||||
bat_terminal = &hv_terminal;
|
||||
solar_terminal = &lv_terminal;
|
||||
dc_bus_init_solar(solar_terminal, DCDC_CURRENT_MAX);
|
||||
solar_terminal->init_solar(DCDC_CURRENT_MAX);
|
||||
break;
|
||||
}
|
||||
#endif
|
||||
charger_detect_num_batteries(&charger, &bat_conf, bat_terminal); // check if we have 24V instead of 12V system
|
||||
battery_init_dc_bus(bat_terminal, &bat_conf, charger.num_batteries);
|
||||
|
||||
charger.detect_num_batteries(&bat_conf); // check if we have 24V instead of 12V system
|
||||
battery_init_dc_bus(&lv_bus, bat_terminal, &bat_conf, charger.num_batteries);
|
||||
|
||||
wait(2); // safety feature: be able to re-flash before starting
|
||||
control_timer_start(CONTROL_FREQUENCY);
|
||||
@@ -189,12 +198,12 @@ int main()
|
||||
|
||||
//printf("Still alive... time: %d, mode: %d\n", (int)time(NULL), dcdc.mode);
|
||||
|
||||
battery_discharge_control(bat_terminal, &bat_conf, &charger);
|
||||
battery_charge_control(bat_terminal, &bat_conf, &charger);
|
||||
charger.discharge_control(&bat_conf);
|
||||
charger.charge_control(&bat_conf);
|
||||
|
||||
charger_update_junction_bus(&lv_bus_int, bat_terminal, &load_terminal);
|
||||
update_dcdc_current_targets(&dcdc_port_lv, bat_terminal, &load_terminal);
|
||||
|
||||
load_state_machine(&load);
|
||||
load.state_machine();
|
||||
|
||||
eeprom_update();
|
||||
|
||||
|
||||
Reference in New Issue