PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each connection to a junction, as described in issue #50. With this commit, also some structs were converted to C++ classes to improve readibility of the code and make sure that pointers (e.g. to PowerPort objects) are always assigned during initialization.
This commit is contained in:
+48
-46
@@ -25,7 +25,7 @@
|
||||
#include <stdint.h>
|
||||
#include <stdbool.h>
|
||||
|
||||
#include "dc_bus.h"
|
||||
#include "power_port.h"
|
||||
|
||||
/** DC/DC basic operation mode
|
||||
*
|
||||
@@ -54,19 +54,55 @@ enum DcdcControlState
|
||||
DCDC_STATE_DERATING ///< Hardware-limits (current or temperature) reached
|
||||
};
|
||||
|
||||
/** DC/DC type
|
||||
/** DC/DC class
|
||||
*
|
||||
* Contains all data belonging to the DC/DC sub-component of the PCB, incl.
|
||||
* actual measurements and calibration parameters.
|
||||
*/
|
||||
typedef struct {
|
||||
class Dcdc
|
||||
{
|
||||
public:
|
||||
/** Initialize DC/DC and DC/DC port structs
|
||||
*
|
||||
* See http://libre.solar/docs/dcdc_control for detailed information
|
||||
*
|
||||
* @param hv_side High voltage terminal (e.g. solar input for MPPT buck)
|
||||
* @param lv_side Low voltage terminal (e.g. battery output for MPPT buck)
|
||||
* @param mode Operation mode (buck, boost or nanogrid)
|
||||
*/
|
||||
Dcdc(PowerPort *hv_side, PowerPort* lv_side, DcdcOperationMode mode);
|
||||
|
||||
/** Check for valid start conditions of the DC/DC converter
|
||||
*
|
||||
* @returns 1 for buck mode, -1 for boost mode and 0 for invalid conditions
|
||||
*/
|
||||
int check_start_conditions();
|
||||
|
||||
/** Main control function for the DC/DC converter
|
||||
*
|
||||
* If DC/DC is off, this function checks start conditions and starts conversion if possible.
|
||||
*/
|
||||
void control();
|
||||
|
||||
/** Test mode for DC/DC, ramping up to 50% duty cycle
|
||||
*/
|
||||
void test();
|
||||
|
||||
/** Prevent overcharging of battery in case of shorted HS MOSFET
|
||||
*
|
||||
* This function switches the LS MOSFET continuously on to blow the battery input fuse. The
|
||||
* reason for self destruction should be logged and stored to EEPROM prior to calling this
|
||||
* function, as the charge controller power supply will be cut after the fuse is destroyed.
|
||||
*/
|
||||
void self_destruction();
|
||||
|
||||
DcdcOperationMode mode; ///< DC/DC mode (buck, boost or nanogrid)
|
||||
bool enabled; ///< Can be used to disable the DC/DC power stage
|
||||
uint16_t state; ///< Control state (off / MPPT / CC / CV)
|
||||
|
||||
// actual measurements
|
||||
DcBus *hv_bus; ///< Pointer to DC bus at high voltage side
|
||||
DcBus *lv_bus; ///< Pointer to DC bus at low voltage (inductor) side
|
||||
PowerPort *hvs; ///< Pointer to DC bus at high voltage side
|
||||
PowerPort *lvs; ///< Pointer to DC bus at low voltage (inductor) side
|
||||
float temp_mosfets; ///< MOSFET temperature measurement (if existing)
|
||||
|
||||
// current state
|
||||
@@ -85,47 +121,13 @@ typedef struct {
|
||||
// calibration parameters
|
||||
int restart_interval; ///< Restart interval (s): When should we retry to start charging
|
||||
///< after low output power cut-off?
|
||||
} Dcdc;
|
||||
|
||||
|
||||
/** Initialize DC/DC and DC/DC port structs
|
||||
*
|
||||
* See http://libre.solar/docs/dcdc_control for detailed information
|
||||
*
|
||||
* @param dcdc DC/DC object
|
||||
* @param hv High voltage terminal (e.g. solar input for MPPT buck)
|
||||
* @param lv Low voltage terminal (e.g. battery output for MPPT buck)
|
||||
* @param mode Operation mode (buck, boost or nanogrid)
|
||||
*/
|
||||
void dcdc_init(Dcdc *dcdc, DcBus *hv, DcBus *lv, DcdcOperationMode mode);
|
||||
|
||||
/** Check for valid start conditions of the DC/DC converter
|
||||
*
|
||||
* @param dcdc DC/DC object incl. measurement data
|
||||
* @returns 1 for buck mode, -1 for boost mode and 0 for invalid conditions
|
||||
*/
|
||||
int dcdc_check_start_conditions(Dcdc *dcdc);
|
||||
|
||||
/** Main control function for the DC/DC converter
|
||||
*
|
||||
* If DC/DC is off, this function checks start conditions and starts conversion if possible.
|
||||
*
|
||||
* @param dcdc DC/DC object incl. measurement data
|
||||
*/
|
||||
void dcdc_control(Dcdc *dcdc);
|
||||
|
||||
/** Test mode for DC/DC, ramping up to 50% duty cycle
|
||||
*
|
||||
* @param dcdc DC/DC object incl. measurement data
|
||||
*/
|
||||
void dcdc_test(Dcdc *dcdc);
|
||||
|
||||
/** Prevent overcharging of battery in case of shorted HS MOSFET
|
||||
*
|
||||
* This function switches the LS MOSFET continuously on to blow the battery input fuse. The reason for self destruction should
|
||||
* be logged and stored to EEPROM prior to calling this function, as the charge controller power supply will be cut after the
|
||||
* fuse is destroyed.
|
||||
*/
|
||||
void dcdc_self_destruction();
|
||||
private:
|
||||
/** Calculates the duty cycle change depending on operating mode and actual measurements
|
||||
*
|
||||
* @returns duty cycle step (-1 or 1) or 0 if DC/DC should be switched off
|
||||
*/
|
||||
int duty_cycle_delta();
|
||||
};
|
||||
|
||||
#endif /* DCDC_H */
|
||||
|
||||
Reference in New Issue