PowerPort added to store current independent from DC bus type

The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
This commit is contained in:
Martin Jaeger
2019-10-20 14:52:35 +02:00
parent d7ed3cdd13
commit 0399c4e877
25 changed files with 860 additions and 823 deletions
+102 -119
View File
@@ -18,10 +18,6 @@
#include "config.h"
#include "pcb.h"
#include "dc_bus.h"
#include "load.h"
#include "log.h"
#include <math.h> // for fabs function
#include <stdio.h>
#include <time.h>
@@ -219,20 +215,11 @@ void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *char
// - restart DC/DC
}
void charger_init(Charger *charger)
{
charger->num_batteries = 1; // initialize with only one battery in series
charger->soh = 100; // assume new battery
charger->bat_temperature = 25.0;
charger->first_full_charge_reached = false;
}
void charger_detect_num_batteries(Charger *charger, BatConf *bat, DcBus *bus)
void Charger::detect_num_batteries(BatConf *bat)
{
if (bus->voltage > bat->voltage_absolute_min * 2 &&
bus->voltage < bat->voltage_absolute_max * 2) {
charger->num_batteries = 2;
num_batteries = 2;
printf("Detected two batteries (total %.2f V max)\n", bat->topping_voltage * 2);
}
else {
@@ -240,11 +227,11 @@ void charger_detect_num_batteries(Charger *charger, BatConf *bat, DcBus *bus)
}
}
void battery_update_soc(BatConf *bat_conf, Charger *charger, DcBus *bus)
void Charger::update_soc(BatConf *bat_conf)
{
static int soc_filtered = 0; // SOC / 100 for better filtering
if (fabs(bus->current) < 0.2) {
if (fabs(port->current) < 0.2) {
int soc_new = (int)((bus->voltage - bat_conf->ocv_empty) /
(bat_conf->ocv_full - bat_conf->ocv_empty) * 10000.0);
@@ -263,162 +250,163 @@ void battery_update_soc(BatConf *bat_conf, Charger *charger, DcBus *bus)
else if (soc_filtered < 0) {
soc_filtered = 0;
}
charger->soc = soc_filtered / 100;
soc = soc_filtered / 100;
}
charger->discharged_Ah += -bus->current / 3600.0; // charged current is positive: change sign
discharged_Ah += -port->current / 3600.0; // charged current is positive: change sign
}
static void _enter_state(Charger* charger, int next_state)
void Charger::enter_state(int next_state)
{
//printf("Enter State: %d\n", next_state);
charger->time_state_changed = time(NULL);
charger->state = next_state;
time_state_changed = time(NULL);
state = next_state;
}
void battery_discharge_control(DcBus *bus, BatConf *bat_conf, Charger *charger)
void Charger::discharge_control(BatConf *bat_conf)
{
// load output state is defined by battery bus dis_allowed flag
if (bus->dis_current_limit < 0 // discharging allowed
&& bus->voltage < charger->num_batteries *
(bat_conf->voltage_load_disconnect - bus->current * bus->dis_droop_res))
if (port->dis_current_limit < 0 // discharging allowed
&& bus->voltage < num_batteries *
(bat_conf->voltage_load_disconnect - port->current * port->dis_droop_res))
{
// low state of charge
bus->dis_current_limit = 0;
charger->num_deep_discharges++;
port->dis_current_limit = 0;
num_deep_discharges++;
if (charger->usable_capacity < 0.1) {
if (usable_capacity < 0.1) {
// reset to measured value if discharged the first time
if (charger->first_full_charge_reached) {
charger->usable_capacity = charger->discharged_Ah;
if (first_full_charge_reached) {
usable_capacity = discharged_Ah;
}
} else {
}
else {
// slowly adapt new measurements with low-pass filter
charger->usable_capacity =
0.8 * charger->usable_capacity +
0.2 * charger->discharged_Ah;
usable_capacity =
0.8 * usable_capacity +
0.2 * discharged_Ah;
}
// simple SOH estimation
charger->soh = charger->usable_capacity / bat_conf->nominal_capacity;
soh = usable_capacity / bat_conf->nominal_capacity;
}
else if (bus->dis_current_limit < 0
&& (charger->bat_temperature > bat_conf->discharge_temp_max
|| charger->bat_temperature < bat_conf->discharge_temp_min))
else if (port->dis_current_limit < 0
&& (bat_temperature > bat_conf->discharge_temp_max
|| bat_temperature < bat_conf->discharge_temp_min))
{
// temperature limits exceeded
bus->dis_current_limit = 0;
port->dis_current_limit = 0;
}
if (bus->voltage >= charger->num_batteries *
(bat_conf->voltage_load_reconnect - bus->current * bus->dis_droop_res)
&& charger->bat_temperature < bat_conf->discharge_temp_max - 1
&& charger->bat_temperature > bat_conf->discharge_temp_min + 1)
if (bus->voltage >= num_batteries *
(bat_conf->voltage_load_reconnect - port->current * port->dis_droop_res)
&& bat_temperature < bat_conf->discharge_temp_max - 1
&& bat_temperature > bat_conf->discharge_temp_min + 1)
{
// discharge current is stored as absolute value in bat_conf, but defined
// as negative current for dc_bus
bus->dis_current_limit = -bat_conf->discharge_current_max;
port->dis_current_limit = -bat_conf->discharge_current_max;
}
}
void battery_charge_control(DcBus *bus, BatConf *bat_conf, Charger *charger)
void Charger::charge_control(BatConf *bat_conf)
{
// check battery temperature for charging direction
if (charger->bat_temperature > bat_conf->charge_temp_max
|| charger->bat_temperature < bat_conf->charge_temp_min)
if (bat_temperature > bat_conf->charge_temp_max
|| bat_temperature < bat_conf->charge_temp_min)
{
bus->chg_current_limit = 0;
_enter_state(charger, CHG_STATE_IDLE);
port->chg_current_limit = 0;
enter_state(CHG_STATE_IDLE);
}
// state machine
switch (charger->state) {
switch (state) {
case CHG_STATE_IDLE: {
if (bus->voltage < bat_conf->voltage_recharge * charger->num_batteries
&& (time(NULL) - charger->time_state_changed) > bat_conf->time_limit_recharge
&& charger->bat_temperature < bat_conf->charge_temp_max - 1
&& charger->bat_temperature > bat_conf->charge_temp_min + 1)
if (bus->voltage < bat_conf->voltage_recharge * num_batteries
&& (time(NULL) - time_state_changed) > bat_conf->time_limit_recharge
&& bat_temperature < bat_conf->charge_temp_max - 1
&& bat_temperature > bat_conf->charge_temp_min + 1)
{
bus->chg_voltage_target = charger->num_batteries * (bat_conf->topping_voltage +
bat_conf->temperature_compensation * (charger->bat_temperature - 25));
bus->chg_current_limit = bat_conf->charge_current_max;
charger->full = false;
_enter_state(charger, CHG_STATE_BULK);
bus->chg_voltage_target = num_batteries * (bat_conf->topping_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
port->chg_current_limit = bat_conf->charge_current_max;
full = false;
enter_state(CHG_STATE_BULK);
}
break;
}
case CHG_STATE_BULK: {
// continuously adjust voltage setting for temperature compensation
bus->chg_voltage_target = charger->num_batteries * (bat_conf->topping_voltage +
bat_conf->temperature_compensation * (charger->bat_temperature - 25));
bus->chg_voltage_target = num_batteries * (bat_conf->topping_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
if (bus->voltage > charger->num_batteries *
(bus->chg_voltage_target - bus->current * bus->chg_droop_res))
if (bus->voltage > num_batteries *
(bus->chg_voltage_target - port->current * port->chg_droop_res))
{
_enter_state(charger, CHG_STATE_TOPPING);
enter_state(CHG_STATE_TOPPING);
}
break;
}
case CHG_STATE_TOPPING: {
// continuously adjust voltage setting for temperature compensation
bus->chg_voltage_target = charger->num_batteries * (bat_conf->topping_voltage +
bat_conf->temperature_compensation * (charger->bat_temperature - 25));
bus->chg_voltage_target = num_batteries * (bat_conf->topping_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
if (bus->voltage >= charger->num_batteries *
(bus->chg_voltage_target - bus->current * bus->chg_droop_res))
if (bus->voltage >= num_batteries *
(bus->chg_voltage_target - port->current * port->chg_droop_res))
{
charger->time_voltage_limit_reached = time(NULL);
time_voltage_limit_reached = time(NULL);
}
// cut-off limit reached because battery full (i.e. CV limit still
// reached by available solar power within last 2s) or CV period long enough?
if ((bus->current < bat_conf->topping_current_cutoff &&
(time(NULL) - charger->time_voltage_limit_reached) < 2)
|| (time(NULL) - charger->time_state_changed) > bat_conf->topping_duration)
if ((port->current < bat_conf->topping_current_cutoff &&
(time(NULL) - time_voltage_limit_reached) < 2)
|| (time(NULL) - time_state_changed) > bat_conf->topping_duration)
{
charger->full = true;
charger->num_full_charges++;
charger->discharged_Ah = 0; // reset coulomb counter
charger->first_full_charge_reached = true;
full = true;
num_full_charges++;
discharged_Ah = 0; // reset coulomb counter
first_full_charge_reached = true;
if (bat_conf->equalization_enabled && (
(time(NULL) - charger->time_last_equalization) / (24*60*60)
(time(NULL) - time_last_equalization) / (24*60*60)
>= bat_conf->equalization_trigger_days ||
charger->num_deep_discharges - charger->deep_dis_last_equalization
num_deep_discharges - deep_dis_last_equalization
>= bat_conf->equalization_trigger_deep_cycles))
{
bus->chg_voltage_target = bat_conf->equalization_voltage;
bus->chg_current_limit = bat_conf->equalization_current_limit;
_enter_state(charger, CHG_STATE_EQUALIZATION);
port->chg_current_limit = bat_conf->equalization_current_limit;
enter_state(CHG_STATE_EQUALIZATION);
}
else if (bat_conf->trickle_enabled) {
bus->chg_voltage_target = charger->num_batteries * (bat_conf->trickle_voltage +
bat_conf->temperature_compensation * (charger->bat_temperature - 25));
_enter_state(charger, CHG_STATE_TRICKLE);
bus->chg_voltage_target = num_batteries * (bat_conf->trickle_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
enter_state(CHG_STATE_TRICKLE);
}
else {
bus->chg_current_limit = 0;
_enter_state(charger, CHG_STATE_IDLE);
port->chg_current_limit = 0;
enter_state(CHG_STATE_IDLE);
}
}
break;
}
case CHG_STATE_TRICKLE: {
// continuously adjust voltage setting for temperature compensation
bus->chg_voltage_target = charger->num_batteries * (bat_conf->trickle_voltage +
bat_conf->temperature_compensation * (charger->bat_temperature - 25));
bus->chg_voltage_target = num_batteries * (bat_conf->trickle_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
if (bus->voltage >= charger->num_batteries *
(bus->chg_voltage_target - bus->current * bus->chg_droop_res))
if (bus->voltage >= num_batteries *
(bus->chg_voltage_target - port->current * port->chg_droop_res))
{
charger->time_voltage_limit_reached = time(NULL);
time_voltage_limit_reached = time(NULL);
}
if (time(NULL) - charger->time_voltage_limit_reached > bat_conf->trickle_recharge_time)
if (time(NULL) - time_voltage_limit_reached > bat_conf->trickle_recharge_time)
{
bus->chg_current_limit = bat_conf->charge_current_max;
charger->full = false;
_enter_state(charger, CHG_STATE_BULK);
port->chg_current_limit = bat_conf->charge_current_max;
full = false;
enter_state(CHG_STATE_BULK);
}
// assumption: trickle does not harm the battery --> never go back to idle
// (for Li-ion battery: disable trickle!)
@@ -426,26 +414,26 @@ void battery_charge_control(DcBus *bus, BatConf *bat_conf, Charger *charger)
}
case CHG_STATE_EQUALIZATION: {
// continuously adjust voltage setting for temperature compensation
bus->chg_voltage_target = charger->num_batteries * (bat_conf->equalization_voltage +
bat_conf->temperature_compensation * (charger->bat_temperature - 25));
bus->chg_voltage_target = num_batteries * (bat_conf->equalization_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
// current or time limit for equalization reached
if (time(NULL) - charger->time_state_changed > bat_conf->equalization_duration)
if (time(NULL) - time_state_changed > bat_conf->equalization_duration)
{
// reset triggers
charger->time_last_equalization = time(NULL);
charger->deep_dis_last_equalization = charger->num_deep_discharges;
time_last_equalization = time(NULL);
deep_dis_last_equalization = num_deep_discharges;
charger->discharged_Ah = 0; // reset coulomb counter again
discharged_Ah = 0; // reset coulomb counter again
if (bat_conf->trickle_enabled) {
bus->chg_voltage_target = charger->num_batteries * (bat_conf->trickle_voltage +
bat_conf->temperature_compensation * (charger->bat_temperature - 25));
_enter_state(charger, CHG_STATE_TRICKLE);
bus->chg_voltage_target = num_batteries * (bat_conf->trickle_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
enter_state(CHG_STATE_TRICKLE);
}
else {
bus->chg_current_limit = 0;
_enter_state(charger, CHG_STATE_IDLE);
port->chg_current_limit = 0;
enter_state(CHG_STATE_IDLE);
}
}
break;
@@ -453,37 +441,32 @@ void battery_charge_control(DcBus *bus, BatConf *bat_conf, Charger *charger)
}
}
void battery_init_dc_bus(DcBus *bus, BatConf *bat, unsigned int num_batteries)
void battery_init_dc_bus(DcBus *bus, PowerPort *port, BatConf *bat, unsigned int num_batteries)
{
unsigned int n = (num_batteries == 2 ? 2 : 1); // only 1 or 2 allowed
bus->dis_voltage_start = bat->voltage_load_reconnect * n;
bus->dis_voltage_stop = bat->voltage_load_disconnect * n;
bus->dis_current_limit = -bat->discharge_current_max;
port->dis_current_limit = -bat->discharge_current_max;
// negative sign for compensation of actual resistance
bus->dis_droop_res = -(bat->internal_resistance + -bat->wire_resistance) * n;
port->dis_droop_res = -(bat->internal_resistance + -bat->wire_resistance) * n;
bus->chg_voltage_target = bat->topping_voltage * n;
bus->chg_voltage_min = bat->voltage_absolute_min * n;
bus->chg_current_limit = bat->charge_current_max;
port->chg_current_limit = bat->charge_current_max;
// negative sign for compensation of actual resistance
bus->chg_droop_res = -bat->wire_resistance * n;
port->chg_droop_res = -bat->wire_resistance * n;
}
void charger_update_junction_bus(DcBus *junction, DcBus *bat, DcBus *load)
void update_dcdc_current_targets(PowerPort *dcdc_port, PowerPort *bat, PowerPort *load)
{
// relevant for DC/DC
junction->chg_current_limit = bat->chg_current_limit - bat->current + load->current;
junction->chg_voltage_target = bat->chg_voltage_target;
// relevant for load output
junction->dis_voltage_start = bat->dis_voltage_start;
junction->dis_voltage_stop = bat->dis_voltage_stop;
dcdc_port->chg_current_limit = bat->chg_current_limit - bat->current + load->current;
// this is a bit tricky... in theory, we could add the available DC/DC current to keep the
// load switched on as long as solar power is available, even if the battery is empty. This
// needs a fast point-of-load (PoL) control of the DC/DC, which is not possible (yet).
junction->dis_current_limit = bat->dis_current_limit - bat->current;
dcdc_port->dis_current_limit = bat->dis_current_limit - bat->current;
}